OPS
Operational mode of the transceiver
00 Idle Mode
01 Data Mode
10 Startup handshake in progress
18 Startup training in progress
80 Local analog loopback
PID
Pair Identification when 4p operation is enabled
PWR
Transmit power of each channel [dBm]
UPS
Unit Power Source
01 locally powered
02 remotely powered
PRA
Current state of the digital section (DS) according to ETS 300 233 sec-
tion 9.4. Only the states possible in NT1 & LT mode are displayed. The
PRA status is shown in PRA mode only
00 NTU dying
01 NTU dying & FV3/FC5
02 NTU dying & FC4
03 NTU dying & FC4 & FV3/FC5
04 NTU dying & AIS
05 NTU dying & AIS & FC4
06 Normal function
07 FC4
08 FV3/FC5
09 FV3/FC5 & FC4
10 Loopback 1
11 Loopback 1 & FC4
12 Loopback 2
13 Loopback 2 & FC4
14 Loopback 1 & NTU dying
15 Loopback 1 & NTU dying & FC4
16 Loopback 2 & NTU dying
16 Loopback 2 & NTU dying & FC4
18 AIS
19 AIS & FC4
Note:
In multipair modems the status values will be displayed per pair with suffix –A, -