Specifications
Watson-TDM-Manual-W.doc
Version 2.0-01
Watson TDM
Operating Manual
Revision: 2008-02-07 8-15
LTU_01_CM> DIAGNOSTIC
---------------------------------------------+--------------------
Diagnostic: SQ G.826(ES) Attn Status | Alarms
---------------------------------------------+--------------------
LTU-A: +16.0 00000007 +00.26 Sync |
LTU-B: +16.5 00000009 +00.49 Sync |
---------------------------------------------+--------------------
REG-RA: +24.0 00000001 +00.00 Sync |
REG-RB: +24.0 00000001 +00.00 Sync |
REG-CA: +18.5 00000020 +00.00 Sync |
REG-CB: +17.5 00000009 +00.00 Sync |
---------------------------------------------+--------------------
NTU-A: +16.0 00000000 +00.31 Sync |
NTU-B: +16.0 00000000 +00.39 Sync |
Notes:
• Upper part (LTU - lines) contains local, lower window (NTU - lines) contains
remote diagnostic information
• The command will only show the status of the equipped pairs (A, A and B,
A/B/C/D depending on modem type)
• A DSL Slave displays only local information
• In case of an NTU-NTU or LTU-LTU connection, the unit designators are
changed accordingly
• The DIAGNOSTIC command is available from all menus by typing DIA. Help
information is only displayed from the Fault and Maintenance Management
menu.
• If the output of the DIAGNOSTIC command is longer than 22 lines (more than
4 Regenerators in a 1 pair link), the monitor display can be scrolled by press-
ing <Space>
STATUS
The STATUS command displays the current system status:
LTU_01_FMM> STATUS
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local System Status V4.0
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
SYNC-A: 02 OPS-A: 01 PID-A: 01 PWR-A: +13.50 UPS: 01
SYNC-B: 02 OPS-B: 01 PID-B: 02 PWR-B: +13.50
SYNC
Status of SHDSL synchronization according to ETSI TS 101 524.
00 Out of Sync State
01 State 0
02 In Sync State
03 State 1
04 State 2
05 State 3
06 State 4
07 State 5