Revision: 2008-02-07 8-9
MP mode
The MP command sets the E1 mapping mode (see 3.5)
MP 0 : TS0 generated locally in the modem, TS16 only if frE1 > 16
MP 1 : TS0 always transmitted, TS16 only if frE1 > 16
MP 2 : TS0 generated locally in the modem, TS16 always transmitted
MP 3 : TS0 and TS16 always transmitted
MP 4: TS0 and TS16 generated locally in the modem
MP 5: TS0 always transmitted, TS16 generated locally in the modem
Multiservice only:
MP ON: switch E1 Port on
MP OFF: switch E1 Port off
The MP command without parameters displays the E1 timeslot mapping mode.
LTU_01_CM> MP
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
E1 Timeslot Map (Mode: 1)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
TS 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3
Nr 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
Tx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Rx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
TS Nr
Timeslot number (0 .. 31)
Tx
Rx
Timeslot mapping in transceive (towards DSL) and receive (towards E1) direc-
tions:
0 timeslot is not mapped to DSL
1 timeslot is mapped to DSL
N timeslot is mapped to DSL and contains nx64 data
- timeslot unused (Multiservice only)
Notes:
Tx mapping is given by the local configuration, Rx mapping by the mapping
mode configured on the remote site. Theoretically it is possible to use different
mapping modes in each direction. However this is not recommended. If Tx and
Rx mapping are not equal, a warning message is displayed.
In Multipoint operation the MP command has other parameters, see chapter
3.6.
UIF Interface-type
Set the user interface type
E1 E1 user interface
PRA E1 user interface with PRA functions
V35 nx64 interface with V.35
V36 nx64 interface with V.36
X21 nx64 interface with X.21