Specifications

Watson TDM
Operating Manual
Watson-TDM-Manual-W.doc
Version 2.0-01
6-4
Revision: 2008-02-07
6.4 Alarm Relays
The ACU2R [2], the minirack mechanics [7] and the plug-in tabletop housing [8]
have two alarm relays to signal urgent and non-urgent alarms:
Urgent Alarm:
At least one of the plug-in LEDs displays an urgent alarm
Power failure of both –48V
DC
supplies
Non-urgent Alarm:
At least one of the plug-in LEDs displays a non-urgent alarm and none of the
LEDs displays an urgent alarm
Power failure of one of the –48 V
DC
supplies
6.5 Initialization Errors
At system startup, various hardware selftests are performed. If any initialization
errors occur, the startup procedure will be aborted and the monitor will display an
initialization error code in hexadecimal representation. The table below lists the
possible initialization errors and their corresponding error codes:.
Error Code Initialization Error
0x01
Microcontroller RAM test failure
0x04
Framer initialization failure
0x08
DSL transceiver failure (Loop A)
0x10
DSL transceiver failure (Loop B)
0x1000
DSL transceiver failure (Loop C)
0x2000
DSL transceiver failure (Loop D)
0x40
Nx64 interface initialization failure
0x100
E1 interface initialization failure
0x8000
Software Copyright Protection Error
Table 6-6: Software Initialization Errors
Several initialization errors might occur simultaneously. In this case the error
code displayed is the logical OR of the individual error codes. For example if
both the microcontroller RAM test fails (error code 0x01) and the framer initializa-
tion fails (error code 0x04) then code 0x05 will be displayed.