6.3 Naming of ports
Many commands of the Monitor relate to a particular port. These ports are identified as follows:
Port Name
Bridge port of 1
st
DSL span DSL1
Bridge port of 2
nd
DSL span DSL2
Bridge port of 3
rd
DSL span DSL3
Bridge port of 4
th
DSL span DSL4
1
st
Ethernet user interface ETH1
2
nd
Ethernet user interface ETH2
3
rd
Ethernet user interface ETH3
4
th
Ethernet user interface ETH4
1
st
Management Ethernet interface (Q) MGMT1
2
nd
Management Interface (Backplane) MGMT2
3
rd
Management Interface (Bridge) MGMT3
Table 6-1: Port naming
Cf. also Figure 3-4.
The number of DSL spans varies depending on the card configuration set by the CARDMODE
command, cf. Table 3-1.
6.4 Telnet Access
To use a remote Monitor through Telnet on the Watson 5 Ethernet plugin you first have to configure
the IP address of the plugin through a monitor on the RS-232 interface with the MGMTIP com-
mand.
Then use any Telnet client to open a telnet session into the modem. You will see a Telnet welcome
screen:
+-----------------------------------------------+
| Welcome to Watson 5 Ethernet Quad LTU |
| (C) by Schmid Telecom AG Zuerich, Switzerland |
+-----------------------------------------------+
OS/HW: Linux ppc 2.4.20
Nodename: SzW5EthLtu
SzW5EthLtu login:
Enter username and password to display the Monitor Welcome Screen.
Note: The default username is root, the default password is sz . It is not possible to change these.