established in this case. Make sure that the DSL span is running before starting
the internal BER test. If the DSL span fails during the internal BER test, the test
must be restarted after the link is re-established.
The test will stop automatically after m minutes; a manual stop is possible with
the STOPBER command.
NTU_PM>STARTBER 3
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
BER Test Results Test running
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Test direction : SHDSL
Test interval : 180
Test pattern : 2^15-1
Test bit rate : 2048000
Bit errors : 0
Bit error rate : 0.00E+00
Sync loss seconds : 0
Elapsed seconds : 51
The display of the BER test status is continuously updated. If you navigate away
from this screen the BER test continues running. The rest results can be dis-
played anytime with the READBER command. Use READBER C to have conti-
nuous updates.
STOPBER
Use STOPBER to immediately terminate a running BER test.
READBER [ C ]
To display the results of a BER test. When a test is running, the current results
are displayed, when no test is running, the results of the last BER test are dis-
played. If the test is running then you can use READBER C to continuously up-
dates the display with the latest BER test results.
NTU_PM> READBER
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
BER Test Results Test stopped
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Test direction : SHDSL
Test interval : 180
Test pattern : 2^15-1
Test bit rate : 2048000
Bit errors : 0
Bit error rate : 0.00E+00
Sync loss seconds : 0
Elapsed seconds : 180