Specifications
Watson Ethernet
Operating Manual
Watson-Ethernet-Manual.doc
Version 3.3-01
7-38
Revision: 2010-01-20
RESETBER
The RESETBER command resets the error and time counters of a BER test.
7.5 Security and Remote Management SM
7.5.1 Connection control
CONNECT Span
The CONNECT (or CON) command establishes a connection over a DSL span to a remote
unit for configuration purposes. This connection uses the DSL EOC for communication.
DISCONNECT
The DISCONNECT (or DIS) command breaks the connection to the remote unit.
In a modem chain the DISCONNECT command will disconnect one modem and
connect to the previous modem in the chain, cf. 3.5.2.
To disconnect an entire chain at once you can type <ESC><ESC>
Notes:
Connection control commands are only available on modems that are confi-
gured as DSL master
The CONNECT and DISCONNECT commands are available from all sub-menus,
but are not displayed in the respective help screens.
7.5.2 Inventory
RCHM
The RCHM command displays the CHM code of the connected device. The CHM
code includes the hardware type identifier, information about hardware and soft-
ware revisions as well as the default delivery settings.
RFW
The RFW command displays the firmware version of the connected device.
RHM
The RHM command displays the HM code of the connected device and displays it
on the terminal.
The HM code includes the serial number of the device as well as information
about manufacturer and warranty.