DITRA-HEAT Installation Handbook

6.625"
1.625"
8.625"
9"
8.625"
Test Results
Test results of assemblies with DITRA-HEAT-DUO and porcelain tile over concrete are listed in the table below. DITRA-HEAT-DUO with
porcelain tile received a rating of ΔIIC 20, a significant contribution to sound rated floor-ceiling designs. To further improve IIC ratings, sound
rated ceilings can be installed below the subfloor. Wood construction sound tests are in progress.
SOUND CONTROL 27
DH-C-TS
Ceramic, porcelain
or stone tile
Schluter SET, Schluter ALL-SET™,
Schluter FAST-SET, or unmodified
thin-set mortar
DITRA-HEAT or DITRA-HEAT-DUO
uncoupling membrane and heating cables
Schluter SET, Schluter ALL-SET,
Schluter FAST-SET, or unmodified
thin-set mortar
Concrete
No. Report
Test Floor Ceiling Results
Schluter
®
-DITRA-HEAT-DUO
1 NGC 7016078 ASTM E2179 Concrete N/A ΔIIC = 20
2 IN17-007 ASTM E492 8" Concrete None IIC = 50
3 IN18_001 ASTM E492 8" Concrete
• 9" wire suspended ceiling with cold
rolled steel and 7/8" furring channel
• R-11 unfaced fiberglass batts
• 5/8" gypsum board
IIC = 67
4 IN17_059 ASTM E492 6" Concrete
• RSIC-1 clips with 7/8" furring channel
• R-11 unfaced fiberglass batts
• 5/8" gypsum board
IIC = 60
No. Report
Floor-Ceiling Sketch
Schluter
®
-DITRA-HEAT-DUO
1 NGC 7016078
2 IN17-007
3 IN18_001
4 IN17_059
*All assemblies featured 12" x 12" porcelain tile over DITRA-HEAT-DUO installed with cement based thin-set mortars and grouts
Tile and underlayment
Floor-ceiling thickness = 8.625"
Floor-ceiling thickness = 17.625"
Floor-ceiling thickness = 8.25"
RSIC-1 Clips
Concrete slab
Steel Wire
Furring
Channel
Concrete slab
Concrete slab
Installation Considerations
In laboratory testing, sound energy transmission is directed through the test specimen only, with negligible transfer through other paths.
The values provide an accurate picture of the sound control characteristics of the test specimen itself. However, floor/ceiling assemblies
may not perform as expected in the field if they are not isolated from adjacent walls to prevent sound energy transfer. Thus, perimeter joints
are not only necessary to accommodate expansion of the tile assembly, but to also prevent “flanking” sound transfer. Schluter
®
-Systems
provides a range of prefabricated movement joint profiles that can be used for these purposes.
Tile and underlayment
Tile and underlayment
Gypsum Board