Specifications
Page -2-
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN
DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT
THE MANUFACTURER.
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED
BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN
CHEMICALS.
HEATER SPECIFICATIONS
Type of Gas: For use with Propane Only
Gas Supply Pressure
to regulator Maximum: Bottle Pressure Minimum: 5 psig (34.5 kPa)
regulator out 28" W.C. (6.97 kPa) (11" W.C. (2.74 kPa) for 30-FAS/SPC-30 and SPC-40)
Electrical Input: 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 100V
Ignition: Direct Spark (manually operated for 30-FAS/SPC-30 heaters)
Primary Flame Control: Thermocouple Operated Gas Valve
High Temperature Control: 240°F (116°C) Minimum Ambient Temp. Rating 0°F (-17.8°C)
Model: 45-FAC / SPC-45 30-FAS / SPC-30 SPC-40 85-FAC / SPC-85 125-FAC / SPC-125
Rating: 25,000 – 45,000 30,000 Btu/hr 40,000 Btu/hr 50,000 – 85,000 75,000 – 125,000
Btu/Hr Btu/hr Btu/hr
(7.3 – 13.2 kW) (8.8 kW) (11.7 kW) (14.6 – 25.0 kW) (21.9 – 36.6 kW)
Fuel Consumption: 1.2 – 2.1 #/hr 1.4 #/hr 1.8 #/hr 2.3 – 3.9 #/hr 3.5 – 5.8 #/hr
(.54 – .95 kg/hr) (.64 kg/hr) (.82 kg/hr) (1.04 – 1.77 kg/hr) (1.59 – 2.63 kg/hr)
Fuel Orifice Port No.: 18 1 18 18 18
Fuel Orifice Port Size: 0.0180” 0.0730” 0.0217" 0.0240” 0.0295"
(0.4572mm) (1.854mm) (0.55mm) (0.6024mm) (0.75mm)
Heated Air Output: 250 cfm 140 cfm 250 cfm 350 cfm 350 cfm
(1.08 cmm) (3.96 cmm) (1.08 cmm) (9.91 cmm) (9.91 cmm)
Average Air Temp. Rise: 170°F (94°C) 250°F (139°C) 160°F (89°C) 200°F (111°C) 400°F (232°C)
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNINGS
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE
READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
Scheu Products Company, Incorporated
Mail: P.O. Box 250, Upland, CA 91785
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
Telephone: 800-325-7057
www.scheuco.com
customerservice@scheuco.com
8653
September 2002ANSI Z83.7/CGA 2.14-2000
Models
30-FAS/SPC-30, SPC-40, 45-FAC/SPC-45, 85-FAC/SPC-85, 125-FAC/SPC125