Operating instructions

Page 2
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1.Check the heater for possible shipping damage. If any
is found, immediately notify your dealer.
2.Follow all of the "Safety Precautions" on page 1,
"Propane Fuel Information on page 4 and "Operating
Information" on page 1.
3.Connect the POL fitting of hose and regulator assembly
to the propane cylinder by rotating the POL nut counter
clock wise into the propane cylinder's valve outlet and
securely tighten with a wrench.
4.Connect the hose to the heater.
5.Securely tighten all gas connections.
6.Open the cylinder's gas valve and check all gas
connections with a soap and water solution. DO NOT
USE A FLAME.
START
1.WARNING: BEFORE LIGHTING PILOT, fully close the
ball valve (turn handle perpendicular to valve body).
2.Fully open the valve on the propane cylinder.
3.Depress red button on safety pilot valve admitting gas to
the pilot. Push and release the piezo button until the
pilot lights, multiple tries may be necessary. Alternately
place a lighted match near the pilot (pilot is above cutout
in the middle pan). If the hose is filled with air, allow a
few minutes for gas to reach the pilot.
4.When the pilot lights, continue to hold the button on the
safety pilot valve depressed for 30 seconds, then
release.
5.If the pilot goes out, wait 5 minutes and repeat the start
procedure.
6.When the pilot remains lit, open the ball valve to light the
main burner (turn handle parallel with valve body) .
CAUTION: Adjusting burn rate to lower than design can
cause sooting.
STOP
1.Securely close valve on the propane cylinder.
2.Close the ball valve (handle perpendicular to valve body).
RESTART AFTER SAFETY SHUTDOWN
1.Securely close valve at propane cylinder.
2.Wait 5 minutes.
3.Restart following "Start" procedure.
MAINTENANCE AND STORAGE
1.The heater should be inspected before each use, and at
least annually by a qualified person.
2.Before each use, check the soft "O" ring seat at the bull-
nose of the POL fitting. If the "O" ring is cut, scuffed,
otherwise damaged, replace it with part number 6681.
3.Turn off the gas at the LP-gas supply cylinder(s) when
the heater is not in use.
4.When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater
must be disconnected and the cylinder(s) removed from
the heater and stored outdoors and in accordance with
Chapter 5 of the standard for Storage and Handling of
Liquefied Petroleum Gases ANSI/NFPA 58-1998.
CAUTION
When the heater is to be operated in the presence of other
people the user is responsible for properly acquainting
those present with the safety precautions, and of the
hazards involved.
SERVICING
A hazardous condition may result if a heater is used that
has been modified or is not functioning properly. When the
heater is working properly:
* The flame is contained within the heater.
* The flame is essentially blue.
* There is no strong disagreeable odor, eye burning or
other physical discomfort.
* There is no smoke or soot internal or external to the
heater.
* There are no unplanned or unexplained shutdowns of
the heater.
The parts list shows the heater as it was constructed. Do
not use a heater which is different from that shown. In this
regard, use only the hose, regulator and cylinder
connection fitting (called a POL fitting) supplied with the
heater. Do not use alternates. For this heater, the regulator
must be set to supply 11" W.C. pressure. If there is any
uncertainty about the regulator setting, have it checked.
A heater which is not working right must be repaired, but
only by a trained, experienced service person. Contact the
factory for the service center closest to you, phone number
(909) 981-5343.
You may also obtain in-warranty or out-of-warranty service
by returning the product postage prepaid to :
Scheu Products Company
8855 Baker Avenue
Rancho Cucamonga, CA 91730
In-warranty products returned to the Service Department will
be repaired with no charge for either parts or labor and will
be returned to you postage prepaid. Please include a brief
statement indicating date, place of purchase, the nature of
the problem and proof of purchase.
Out-of-warranty products returned to the Service
Department will be repaired with a charge for parts and
labor and will be returned to you postage collect.