User Manual

www.scheppach.com www.scheppach.com
GB
|
31 30
|
GB
Petrol must be ¿lled before starting the combustion
engine. While the combustion engine runs or if the
machine is hot, the fuel cap must not be opened and
petrol must not be ¿lled.
Open the fuel cap carefully and slowly. Wa it fo r t he
pressure to equalise and only then remove the tank
cover completely.
Use a suitable funnel or ¿ller pipe for refuelling so
that no fuel can spill onto the combustion engine and
housing or lawn.
Do not over¿ll the fuel tank!
To leave room for the fuel to expand, never ¿ll the
fuel tank beyond the lower edge of the ¿lling nozzle.
Observe additional information in the combustion
engine user manual.
If petrol has overÀowed, do not start the combustion
engine until the petrol-contaminated area has been
cleaned. Avoid starting the engine until the fuel va-
pours have evaporated (wipe dry).
Always wipe up spilled fuel immediately.
If p etrol has got on clothing, it must be changed.
The tank cover must be properly screwed on and
tightened after each refuelling operation. The device
must not be put into operation without the original
tank cover screwed on.
For safety reasons, check fuel line, fuel tank, fuel
cap and connections regularly for damage, ageing
(brittleness), tight ¿t and leaks and replace if nec-
essary.
Only empty the tank outdoors.
Never use beverage bottles or similar to dispose of
or store operating materials, such as fuel. People,
especially children, could be tempted to drink from it.
Never store the device with petrol in the tank inside
a building. Any fuel vapours produced can come into
contact with naked Àames or sparks and ignite.
Do not place the device and fuel tank near heaters,
radiant heaters, welding machines or other sources
of heat.
Risk of explosion!
If a defect is detected on the tank, the tank cover or
on fuelcarrying parts (fuel lines) during operation, the
combustion engine must be switched o immediately.
Then consult a specialist dealer.
Residual risks
The electric tool has been built according to state-
oftheart and the recognised technical safety rules.
However, individual residual risks can arise during op-
eration.
Electrical safety
1. Prior to use, the generator and its electrical equip-
ment (including lines and plug connectors) should
be checked to ensure that there are no defects.
2. The power generating unit must not be connected
to another power source such as the power sup-
ply of energy supply companies. In special cases
where a reserve connection to existing electrical
systems is provided, this must only be carried out
by a quali¿ed electrician who will take into account
the dierences between the operated equipment
using the public mains and operation of the power
generating unit. According to this part of ISO 8528,
the dierences in the operating manual must be
speci¿ed.
3. Protection against electric shocks depends on
the circuit breakers which are matched precisely
to the power generating unit. If a circuit breaker
must be replaced, this should be done using a cir-
cuit breaker with the same rating and performance
character istics.
Warning! This power tool generates an electromag-
netic ¿eld during operation. This ¿eld can impair active
or passive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
ATTENTION: Use only E10 unleaded petrol as fuel.
m Use of petrol
m Danger to life! Petrol is toxic and highly Àam-
mable.
Only store petrol in containers (canisters) designed
and tested for this purpose. The tank caps must al-
ways be properly screwed on and tightened. Defec-
tive caps must be replaced for safety reasons.
Keep petrol away from sparks, open Àames, per-
manent Àames, heat sources and other sources of
ignition. Do not smoke!
Refuel outdoors only and do not smoke while refu-
elling.
Before refuelling, switch o the combustion engine
and let it cool down.
Operating mode S1 (continuous operation)
The machine may be operated continuously with the
speci¿ed power.
Operating mode S2 (short-term operation)
The machine may only be operated at maximum or
peak power for a brief time.
Noise and vibration
m Warning: Noise can have serious eects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Information on noise level per EN ISO 3744:1995,
ISO 8528-10:1998
Noise data
Sound power level L
WA
96 dB
Sound pressure level L
pA
74.6 dB
Uncertainty K
wa/pA
1.5 dB
7. Unpacking
Open the packaging and carefully remove the de-
vice.
Remove the packaging material, as well as the pack-
aging and transport safety devices (if present).
Check whether the scope of delivery is complete.
Check the device and accessory parts for transport
damage. In the event of complaints the carrier must
be informed immediately. Later claims will not be
recognised.
If possible, keep the packaging until the expiry of the
warranty period.
Familiarise yourself with the device by means of the
operating manual before using for the ¿rst time.
With accessories as well as wearing parts and spare
parts use only original parts. Spare parts can be ob-
tained from your specialist dealer.
When ordering please provide our article number as
well as type and year of manufacture for your equip-
ment.
m WARNING!
The device and the packaging material are not
childrens toys! Do not let children play with plas-
tic bags, ¿lms or small parts! There is a danger of
choking or suocating!
Health hazard due to electrical power, with the use
of improper electrical connection cables.
Furthermore, despite all precautions having been
met, some nonobvious residual risks may still re-
main.
Residual risks can be minimised if the Safety infor-
mation” and the Proper use” together with the oper-
ating manual as a whole are observed.
Avoid accidental start-ups of the power generator.
Use the device in the way that is recommended in
this operating manual. This is how to ensure that
your power generator provides optimum perfor-
mance.
6. Technical data
Power generator Digital inverter
Protection category IP23M
Continuous output P
n
(COP)
(230 V) (S1)
3.0 kW
Max. power P
max
(230 V) (S2 5min) 3.2 kW
Max. power P
peak
(230 V) (S2 2s) 3.5 kW
Rated voltage U
n
230 V~
Rated current I
n
2 x 13 A (230 V~)
Rated current I
n
8.0 A (12 V)
Rated current I
n
2 x 2.1 A (USB)
Frequency F
n
50 Hz
Per formance class G1
Active power factor φ 1
Quality class A
Drive motor type
4stroke 1 cylinder
a i r- c o o l e d
Displacement 141 cm
3
Max. power (engine) 3.6 kW / 4.8 PS
Fuel Super E10 petrol
Tank contents 6.3 l
Engine oil type 15W40
Oil volume (approx.) 400 ml
Consumption at full load 1.78 l/h
Max. temperature. 40 °C
Max. altitude
(above mean sea level)
1000 m
Spark plug A7RTC
Technical changes reserved!