Operation Manual
Instruction Manual Electrobloc EBL 101 C
5
Date: 30.09.2008
811.553 BA / EN
³ Disconnect the battery from the Electrobloc by activating the battery iso-
lation on the DT ... control and switch panel (see also section 3.4).
³ Remove ”+ solar cell” connector on the solar charge regulator (if availa-
ble).
³ Isolate Electrobloc from the mains voltage (230 V AC).
³ Replace battery.
³ After changing the battery, recheck which type of battery has been inser-
ted.
Y DANGER!
Incorrect setting of the battery selector switch.
Risk of explosion due to build up of explosive gases:
F Set the battery selector switch to the correct position.
Y ATTENTION!
Incorrect setting of the battery selector switch.
Damage to the battery.
F Set the battery selector switch to the correct position.
³ Disconnect the electronic block from the mains before adjusting the bat-
tery selector switch.
1
Fig. 1 Battery selector switch
³ Set the battery selector switch (Fig. 1, Pos. 1) to the correct position
using a thin object (such as a ballpoint pen):
F Lead gel battery: Set the battery selector switch to ”Lead-gel”.
F Lead acid battery: Set the battery selector switch to ”Lead-acid”.
³ Remove ”+ solar cell” connector on the solar charge regulator (if availa-
ble).
³ St art up the system as described in section 3.1.
Changing the battery
Starting up
the System