Operation Manual
Instruction Manual Electrobloc EBL 101 C
4
Date: 30.09.2008 811.553 BA / EN
Use the 12 V main switch (see instruction manual of relevant control and
switch panel) to switch on/off all the consumers and the control and switch
panel.
Exceptions:
F Heater
F Step
F Frost protection valve
F AES/compressor refrigerator
F Spare 4
For more information, see the DT ... control and switch panel instruction ma-
nual.
The supply to the step is protected by a self-resetting fuse. This is why the
step switch may only be activated briefly.
Y ATTENTION!
Activating the step switch too long results in too high a current.
Self-resetting fuse can activate:
F Only press the step switch briefly.
³ If the self-resetting fuse has triggered, it needs about one minute to reset
before the step switch can be pressed again.
Y ATTENTION!
No battery buffer function!
Damage to connected devices:
F Do not operate solar regulator without battery connected.
3.2 Changing the battery
Y ATTENTION!
Use of incorrect battery types or incorrectly rated batteries.
Damage to the battery or devices connected to the electronic block:
F Batteries should only be changed by qualified personnel.
F Follow the instructions of the battery manufacturer.
F Only connect the electronic block to 12 V power supplies with rechar-
geable 6-cell lead gel or lead acid batteries. Do not use any unsuitable
battery types.
Y Only batteries of the same type and capacity should normally be used,
i.e. same as those installed by the manufacturer.
Y It is possible to swap lead acid batteries with lead gel batteries. Changing
from lead gel batteries to lead acid batteries is not possible without over-
head. Contact the vehicle manufacturer for more information.
Step switch
Operation with solar
regulator