Operation Manual
Instruction Manual Electrobloc EBL 101 C
13
Date: 30.09.2008
811.553 BA / EN
D Fault report
In the event of damage, please return the defective device together with the
completed fault report to the manufacturer.
Device type: _______________________
Article no.: _______________________
Vehicle: Manufacturer: _______________________
Model: _______________________
Own installation? Yes - No -
Upgrade? Yes - No -
Following fault has occurred (please tick):
- Electrical consumers do not work -- which?
(please specify below)
- Switching on and off not possible
- Persistent fault
- Intermittent fault/loose contact
Other remarks:
E Technical data
230 V AC ± 10%, 47 to 63 Hz sinusoidal, protection class I
1.9 A
Depending on the control and switch panel: approx. 5 -- 20 mA, plus con-
sumption of controller electronics of refrigerator
Measurement approx. 10 minutes after disconnection from the mains:
F not connected to mains
F 12.6 V battery voltage
F Battery isolation not enabled
F Control and switch panel lighting off
F 12 V main switch off
Loading of D+ output of the alternator by the Electrobloc approx. 200 mA
without current consumption on D+ point
12 V outputs A maximum of 90% of the nominal
current of the relevant fuse may be
drawn.
Mains connection
Current consumption
Standby current from
living area battery
D+ loading
Current-carrying
capacity