Operation Manual
Instruction Manual Electrobloc EBL 101 C
11
Date: 30.09.2008
811.553 BA / EN
4.2 Additional functions
This relay supplies the AES/compressor refrigerator with power f r om the
starter battery when the vehicle engine is running and the D+ connection is
live. An AES/compressor refrigerator is powered by the living area battery
when the vehicle engine is not running.
The step output is protected by a self-resetting 15 A fuse.
If a fault occurs, such as overcurrent, the self-resetting fuse interrupts the
relevant circuit.
After rectification of the fault, the fuse automatically resets after approx. 1
minute.
Maximum permitted charge current 14 A, protected with 15 A
Depending on the solar charge regulator used, either only the living area
battery is charged or the living area battery and the starter battery.
4.3 Use as an exchange device
The EBL 101 C can be used as an exchange device for the EBL 100. The
plug-and-socket connections of the old device can all be used.
Some additional functions and plug connections of the EBL 101 C will howe-
ver remain without a function.
5 Maintenance
The Electrobloc requires no maintenance.
Clean the electronic block with a soft, slightly damp cloth and mild detergent.
Never use spirit, thinners or similar substances. Do not allow liquids to enter
the electronic block.
No part of this manual may be reproduced, translated or copied without ex-
press written permission.
Automatic switch
function for
AES/compressor
refrigerator
Step fuse
Battery charging with
solar charging regulator
Cleaning