Date: 22.09.2009 822.212 BA / EN
Fault RemedyPossible cause
Batteries are not being
charged
Defective batteries Have the batteries
checked
g
If batteries are in perfect
working order:
Solar charge regulator
defective
Contact the customer
service department
Defective electronic block Contact the customer
service department
Defective wiring Have the wiring checked
5 Technical data
12 V
14.2V for living area and starter battery. Living area battery has priority.
6-cell lead acid or lead gel batteries, rated 55 Ah or higher
T yp. 36-cell modules with the following properties
F
Off-load voltage max. 25 V
F
Overall nominal current max. 18 A
For example, five solar modules each rated at 55W can be connected in pa-
rallel:
Per solar module U
0
=22V
I
nominal
=3.2A
Overall nominal current I
nominal
=16A
F
Schaudt GmbH electroblocs with separate solar current connection
F
Schaudt GmbH electroblocs with retrofit adapter for
charging the starter battery
6 Application and functions in detail
If the solar modules have sufficient charging voltage, the solar charge regu-
lator allows the battery to be charged by up to 14.2 V.
As soon as these voltage is reached, the charging current is reduced to fully
charge the batteries without impairing them. If the charging voltage of the
solar modules is insufficient (e.g. in the dark), an integrated isolation diode
prevents the batteries from discharging.
Living area battery and starter battery are charged simultaneously. The living
area battery has priority.
7 Maintenance
The device requires no maintenance.
Clean the device with a soft, slightly damp cloth and mild detergent. Never
use spirit, thinners or similar substances. Do not allow liquids to enter the
device.
No part of this manual may be reproduced, translated or copied without ex-
press written permission.
Nominal voltage
Final charge voltage
Suitable batteries
Suitable solar modules
Calculation example
Suitable EBL ...
electroblocs
Charging voltage limited
Priority of the
living area battery
Cleaning
E