Datasheet

78
Filter selection table
Choose the family FN xxx with the required body style and features, and add -?? to
determine current rating, and /?? for output connections. Example: FN 9260-1/06 is a
horizontal screw-mounting filter for twin fuses, rated for 1A, with fast-on outputs.
All standard types
FN 9260B types (medical)
-1
-1
-1
-1
-2
-2
-2
-2
-6
-6
-6
-6
-10
-10
-10
-10
-4
-4
-4
-4
5.3 2.7 1 0.3 0.2
Current ratings
A at 40°C (25°)
1 (1.2) 2 (2.3) 4 (4.6) 6 (6.9) 10 (11.5)
Inductance L mH
FN 261
-?? /??
FN 261S
-?? /??
FN 9260
-?? /??
FN 9260S
-?? /??
Family
/06
/06
/06
/06
Output connection
-
-
-
-
Housing
Weight
g
100 2.2
100 -
Capacitance
Cx Cy
nF nF
2000 1700
2500 1700
Filter type
1
1
Res.
R
M
50
50
190
2
Maximum
leakage
µA/phase
250 50/60
250 50/60
Maximum
operating volt.
VAC Hz
Hipot test voltage
PN
E P
N
VAC VDC
Operating
frequency
Hz
DC to 400
DC to 400
MTBF at 40°C, 230V, per Mil-HB-217F: 2,200,000 hours
Additional specifications
Approvals
1
1
2
2
For fuse(s)
Nbr.
See tables for component values
Electrical schematics
N
2xL
Cx
R
FN 261
LINE
LOAD
2xCy
E
P
N'
E'
P'
N
2xL
Cx R
FN 9260 (B-types without Cy capacitors)
LINE
LOAD
2xCy
E
P
N'
E'
P'
EN 133200
IEC 60939
FN 9260
up to 10A current ratings
IEC 950-compliant
for one or two fuses (Ø5 x 20mm)
optional medical version (B type)
Nennstrom bis 10A
IEC 950 konform
Für eine oder zwei Sicherungen (Ø5 x 20mm)
Für medizinische Geräte als Option (Typ B)
courants de service pouvant atteindre 10A
conforme à CEI 950
pour un ou deux fusibles (Ø5 x 20mm)
version médicale en option (type B)