Datasheet
Single-Phase Filters > FN 2080
Filter selection table
Filter*  Rated current  Leakage current**  Inductance  Capacitance  Resistance  Input/Output  Weight 
@ 40°C (25°C)  @ 230VAC/50Hz  L  L1  Cx  Cy  R  connections 
[A]  [mA]  [mH]  [μH]  [μF]  [nF]  [kΩ] 
[g]
FN 2080-1-..  1 (1.2)  0.734  22  490  0.33  4.7  1000  -06  -07  200
FN 2080-3-..  3 (3.5)  0.734  9.8  160  0.47  4.7  470  -06  -07  270
FN 2080-6-..  6 (6.9)  0.734  7.8  110  1 4.7  220  -06  -07  470
FN 2080-10-..  10 (11.5)  0.734  4.5  60  1 4.7  220  -06  -07  750
FN 2080-12-..  12 (13.8)  0.734  3.25  50  1 4.7  220  -06  -07  750
FN 2080-16-..  16 (18.4)  0.734  2.8  43  1 4.7  220  -06  -07  -08  1020
FN 2080A-1-..  1 (1.2)  0.074  22  490  0.33  0.47  1000  -06  -07  200
FN 2080A-3-..  3 (3.5)  0.074  9.8  160  0.47  0.47  470  -06  -07  270
FN 2080A-6-..  6 (6.9)  0.074  7.8  110  1 0.47  220  -06  -07  470
FN 2080A-10-..  10 (11.5)  0.074  4.5  60  1 0.47  220  -06  -07  750
FN 2080A-12-..  12 (13.8)  0.074  3.25  50  1 0.47  220  -06  -07  750
FN 2080A-16-..  16 (18.4)  0.074  2.8  43  1 0.47  220  -06  -07  -08  1020
FN 2080B-1-..  1 (1.2)  0.002  22  490  0.33  1000  -06  -07  200
FN 2080B-3-..  3 (3.5)  0.002  9.8  160  0.47  470  -06  -07  270
FN 2080B-6-..  6 (6.9)  0.002  7.8  110  1 220  -06  -07  470
FN 2080B-10-..  10 (11.5)  0.002  4.5  60  1 220  -06  -07  750
FN 2080B-12-..  12 (13.8)  0.002  3.25  50  1 220  -06  -07  750
FN 2080B-16-..  16 (18.4)  0.002  2.8  43  1 220  -06  -07  -08  1020
* To c ompile a complete part number, please replac e the -.. with the required I/O c onnec tion style (e.g. FN 2080-16-08, FN 2080B-10-06). 
** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Typical filter attenuation
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym