Datasheet
2 EMC/EMI Products Schaffner Group Datasheets 2017
Filter selection table
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L L1 Cx Cy R connections
(@ 120 VAC/60 Hz )
[A] [mA] [mH] [μH] [μF] [nF] [kΩ]
[g]
FN 2080-1-.. 1 (1.2) 0.66 (0.38) 22 490 0.33 4.7 1000 -06 -07 200
FN 2080-3-.. 3 (3.5) 0.66 (0.38) 9.8 160 0.47 4.7 470 -06 -07 270
FN 2080-6-.. 6 (6.9) 0.66 (0.38) 7.8 110 1 4.7 220 -06 -07 470
FN 2080-10-.. 10 (11.5) 0.66 (0.38) 4.5 60 1 4.7 220 -06 -07 750
FN 2080-12-.. 12 (13.8) 0.66 (0.38) 3.25 50 1 4.7 220 -06 -07 750
FN 2080-16-.. 16 (18.4) 0.66 (0.38) 2.8 43 1 4.7 220 -06 -07 -08 1020
FN 2080A-1-.. 1 (1.2) 0.07 (0.04) 22 490 0.33 0.47 1000 -06 -07 200
FN 2080A-3-.. 3 (3.5) 0.07 (0.04) 9.8 160 0.47 0.47 470 -06 -07 270
FN 2080A-6-.. 6 (6.9) 0.07 (0.04) 7.8 110 1 0.47 220 -06 -07 470
FN 2080A-10-.. 10 (11.5) 0.07 (0.04) 4.5 60 1 0.47 220 -06 -07 750
FN 2080A-12-.. 12 (13.8) 0.07 (0.04) 3.25 50 1 0.47 220 -06 -07 750
FN 2080A-16-.. 16 (18.4) 0.07 (0.04) 2.8 43 1 0.47 220 -06 -07 -08 1020
FN 2080B-1-.. 1 (1.2) 0.00 22 490 0.33 1000 -06 -07 200
FN 2080B-3-.. 3 (3.5) 0.00 9.8 160 0.47 470 -06 -07 270
FN 2080B-6-.. 6 (6.9) 0.00 7.8 110 1 220 -06 -07 470
FN 2080B-10-.. 10 (11.5) 0.00 4.5 60 1 220 -06 -07 750
FN 2080B-12-.. 12 (13.8) 0.00 3.25 50 1 220 -06 -07 750
FN 2080B-16-.. 16 (18.4) 0.00 2.8 43 1 220 -06 -07 -08 1020
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2080-16-08, FN 2080B-10-06).
** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Leakage current for DC application is 0 mA;
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
1 to 6 A types
10 and 12 A types
16 A types