Datasheet

IEC Inlet Filters > FN 9260
Filter selection table
Filter
Rated
current Leakage current* Inductance Capacitance Resistance Input/Output Fuses Weight
@ 40°C (25°C) @ 230VAC/50Hz L Cx Cy R connections
[A] [μA] [mH] [μF] [nF] []
[Qty] [g]
FN 9260x-1-06-y 1 (1.2) 373 5.3 0.1 2.2 1000 -06 2 55
FN 9260x-2-06-y 2 (2.3) 373 2.7 0.1 2.2 1000 -06 2 55
FN 9260x-4-06-y 4 (4.6) 373 1.0 0.1 2.2 1000 -06 2 55
FN 9260x-6-06-y 6 (6.9) 373 0.3 0.1 2.2 1000 -06 2 55
FN 9260x-10-06-y 10 (11.5) 373 0.2 0.1 2.2 1000 -06 2 55
FN 9260xA1-1-06-
y
1 (1.2) 37 5.3 0.1 0.22 1000 -06 2 55
FN 9260xA-2-06-y 2 (2.3) 74 2.7 0.1 0.47 1000 -06 2 55
FN 9260xA-4-06-y 4 (4.6) 74 1.0 0.1 0.47 1000 -06 2 55
FN 9260xA-6-06-y 6 (6.9) 74 0.3 0.1 0.47 1000 -06 2 55
FN 9260xA-10-06-
y
10 (11.5) 74 0.2 0.1 0.47 1000 -06 2 55
FN 9260xB-1-06-y 1 (1.2) 2 5.3 0.1 1000 -06 2 55
FN 9260xB-2-06-y 2 (2.3) 2 2.7 0.1 1000 -06 2 55
FN 9260xB-4-06-y 4 (4.6) 2 1.0 0.1 1000 -06 2 55
FN 9260xB-6-06-y 6 (6.9) 2 0.3 0.1 1000 -06 2 55
FN 9260xB-10-06-
y
10 (11.5) 2 0.2 0.1 1000 -06 2 55
FN 261x-1-06-y 1 (1.2) 373 5.3 0.1 2.2 1000 -06 1 55
FN 261x-2-06-y 2 (2.3) 373 2.7 0.1 2.2 1000 -06 1 55
FN 261x-4-06-y 4 (4.6) 373 1.0 0.1 2.2 1000 -06 1 55
FN 261x-6-06-y 6 (6.9) 373 0.3 0.1 2.2 1000 -06 1 55
FN 261x-10-06-y 10 (11.5) 373 0.2 0.1 2.2 1000 -06 1 55
* Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Product selector
For example: FN 9260-1-06-10, FN 9260SB-10-06-20, FN 261S-6-06-30
Typical filter attenuation
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
FN 9260: 1 to 4A types FN 261: 6 and 10A types FN 261: 1 to 4A types FN 261: 6 and 10A types