Datasheet
> Components > FN 612
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 230VAC/50Hz L Cx Cy R connections -03 -06 -10 -24
[A] [µA] [mH] [nF] [nF] [kΩ] [g] [g] [g] [g]
Filter selection table
FN 612-1-06 1 (1.15) 190 3 100 2.2 1000 -06 80
FN 612-3-06 3 (3.4) 190 2 100 2.2 1000 -06 115
FN 612-6-06 6 (6.9) 190 0.75 100 2.2 1000 -06 115
FN 612-10-06 10 (11.5) 190 0.45 100 2.2 1000 -06 115
FN 612-20-.. 20 (23) 190 0.48 100 2.2 1000 -03 -06 -10 290 260 290
FN 612-30-.. 30 (34) 190 0.61 100 2.2 1000 -03 -10 630 630
FN 612-80-24 80 (92) 450 0.2 470 4.7 1000 -24 700
FN 612-100-24 100 (115) 450 0.2 1000 4.7 470 -24 1100
FN 612B-10-06 10 (11.5) 2 0.45 100 1000 -06 115
FN 612B-30-.. 30 (34) 2 0.61 100 1000 -03 -10 630 630
FN 612B-100-24 100 (115) 2 0.2 1000 470 -24 1100
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 612-20-03, FN 612B-30-10).
** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
Typical filter attenuation
1A types 3A types
6 and 10A types 20 and 30A types
80A types 100A types