Datasheet

Features and benefits
FN 2090 two-stage filters are designed
for easy and fast chassis mounting.
The FN 2090 filters are also available as
B versions with no Y-capacitors for
medical applications as well as A
versions with low capacitance for safety
critical applications with a requirement
for low leakage currents.
All filters provide an exceptional
conducted attenuation performance,
based on chokes with high permeable
core material and excellent thermal
behavior.
FN 2090 two-stage filters are designed
for noisy applications requiring
excellent filter performance.
The higher inductivity versus amperage
offers increased attenuation
performance with the same form factor
compared to FN 2060 and FN 2080
filter series.
All FN 2090 filters can be delivered with
optional surge pulse protection.
FN 2090 filters are also available as
singlestage filters (FN 2030 series).
Various terminal options allow you to
select the desired connection style.
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Building automation
Industrial applications
Machinery
Medical equipment
Electronic data processing equipment
Office automation and datacom
equipment
Various noisy applications requiring high
filter performance
Single-Phase Filters
FN 2090
Multi-stage EMI Filter with Excellent
Attenuation Performance
Rated currents from 1 to 30A
Two-stage filter
Very high differential and common-
mode attenuation
Optional medical versions (B type)
Optional safety versions (A type)
Optional overvoltage protection (Z
type)
Approvals
Technical specifications
Maximum continuous operating voltage: 250V, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1 to 30 A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec (standard types)
P –> PE 2500VAC for 2 sec (B types)
P –> N 1100VDC for 2 sec
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN
60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 1,300,000 hours (1 to 10A types)
1,100,000 hours (12A types)
517,000 hours (16 and 30A types)
Surge pulse protection (optional): 2kV, IEC 61000-4-5
Temperature range (operation and
storage):
-25°C to +100°C (25/100/21)
Typical electrical schematic

Summary of content (4 pages)