Datasheet

2 EMC/EMI Products Schaffner Group Datasheets 09 Dec 2021
Filter selection table
Filter* Buy Rated current Leakage current** Power Loss Inductance*** Capacitance*** Resistance*** Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz @25°C/DC L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [W] [mH] [μF] [nF] [kΩ]
[g]
FN2020-1-..
1 (1.15) 0.66 (0.38) 0.8 12 0.15 4.7 1000 -06 -07 80
FN2020-3-..
3 (3.45) 0.66 (0.38) 1.2 2.5 0.15 4.7 1000 -06 -07 80
FN2020-6-..
6 (6.9) 0.66 (0.38) 1.5 1 0.15 4.7 1000 -06 -07 80
FN2020-10-..
10 (11.5) 0.66 (0.38) 2.9 0.8 0.15 4.7 1000 -06 -07 85
FN2020-12-..
12 (13.8) 0.66 (0.38) 3.6 0.7 0.15 4.7 1000 -06 -07 85
FN2020-16-..
16 (18.4) 0.66 (0.38) 2.5 0.65 0.15 4.7 1000 -06 -07 -08 140
FN2020-20-..
20 (23) 0.66 (0.38) 3.8 0.6 0.15 4.7 1000 -06 -08 210
FN2020-30-08
30 (34.5) 0.79 (0.45) 6.3 0.67 0.47 10 470 -08 470
FN2020-60-24
60 (69) 0.79 (0.45) 14.7 1 1.5 10 220 -24 1100
FN2020A-1-..
1 (1.15) 0.07 (0.04) 0.8 12 0.15 0.47 1000 -06 -07 80
FN2020A-3-..
3 (3.45) 0.07 (0.04) 1.2 2.5 0.15 0.47 1000 -06 -07 80
FN2020A-6-..
6 (6.9) 0.07 (0.04) 1.5 1 0.15 0.47 1000 -06 -07 80
FN2020A-10-..
10 (11.5) 0.07 (0.04) 2.9 0.8 0.15 0.47 1000 -06 -07 85
FN2020A-12-..
12 (13.8) 0.07 (0.04) 3.6 0.7 0.15 0.47 1000 -06 -07 85
FN2020A-16-..
16 (18.4) 0.07 (0.04) 2.5 0.65 0.15 0.47 1000 -06 -07 -08 140
FN2020A-20-..
20 (23) 0.07 (0.04) 3.8 0.6 0.15 0.47 1000 -06 -08 210
FN2020A-30-08
30 (34.5) 0.07 (0.04) 6.3 0.67 0.47 0.47 470 -08 470
FN2020A-60-24
60 (69) 0.07 (0.04) 14.7 1 1.5 0.47 220 -24 1100
FN2020B-1-..
1 (1.15) 0.00 0.8 12 0.15 1000 -06 -07 80
FN2020B-3-..
3 (3.45) 0.00 1.2 2.5 0.15 1000 -06 -07 80
FN2020B-6-..
6 (6.9) 0.00 1.5 1 0.15 1000 -06 -07 80
FN2020B-10-..
10 (11.5) 0.00 2.9 0.8 0.15 1000 -06 -07 85
FN2020B-12-..
12 (13.8) 0.00 3.6 0.7 0.15 1000 -06 -07 85
FN2020B-16-..
16 (18.4) 0.00 2.5 0.65 0.15 1000 -06 -07 -08 140
FN2020B-20-..
20 (23) 0.00 3.8 0.6 0.15 1000 -06 -08 210
FN2020B-30-08
30 (34.5) 0.00 6.3 0.67 0.47 470 -08 470
FN2020B-60-24
60 (69) 0.00 14.7 1 1.5 220 -24 1100
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2020-30-08, FN 2020B-10-06).
** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
*** Tolerances apply: Inductance: -30/+50%, Capacitance: ±20%, Resistance: ±10%