Fault messages with fault code
Possible error messages, with a fault code, are shown in the illustration on the left.
Empty the grounds
container!
The last emptying has not been confirmed. ► Pull out the grounds container again, wait
for a short time and reinsert it.
A confirmation query appears on the
display.
► Confirm the display query with [Yes].
Grounds container missing! The grounds container has not been correctly
inserted.
► Check the grounds container for correct
seating.
The monitor sensor is faulty. ► Contact service partner.
The grounds chute is mis-
sing!
The grounds container has not been correctly
inserted.
Only on machines with an under-counter
grounds container!
► Check the grounds container for correct
seating.
The monitor sensor is faulty.
Only on machines with an under-counter
grounds container!
► Contact service partner.
Manual inlet closed? The monitor sensor is faulty. ► Contact service partner.
Display message Cause What to do
Code Designation Cause and effect What to do
6 The brewing unit is
blocked.
The brewing screen is clogged. ► Clean the brewing screen.
See "Cleaning" - "Weekly cleaning".
26 Right mill blocked The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
► Set the grind level to one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. ► Contact your service partner.
36 Left mill blocked The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
► Set the grind level to one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. ► Contact your service partner.