Operation Manual

www.schaerer.com Troubleshooting
BASCV_EN
V03 | 07.2011
66
Fault messages with fault code
Possible error messages, with a fault code, are shown in the illustration on the left.
Empty the grounds
container!
The last emptying has not been confirmed. Pull out the grounds container again, wait
for a short time and reinsert it.
A confirmation query appears on the
display.
Confirm the display query with [Yes].
Grounds container missing! The grounds container has not been correctly
inserted.
Check the grounds container for correct
seating.
The monitor sensor is faulty. Contact service partner.
The grounds chute is mis-
sing!
The grounds container has not been correctly
inserted.
Only on machines with an under-counter
grounds container!
Check the grounds container for correct
seating.
The monitor sensor is faulty.
Only on machines with an under-counter
grounds container!
Contact service partner.
Manual inlet closed? The monitor sensor is faulty. Contact service partner.
Display message Cause What to do
Code Designation Cause and effect What to do
6 The brewing unit is
blocked.
The brewing screen is clogged. Clean the brewing screen.
See "Cleaning" - "Weekly cleaning".
26 Right mill blocked The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
Set the grind level to one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. Contact your service partner.
36 Left mill blocked The grinding fineness setting is too fine.
The fine dust contaminates the mill too quick-
ly.
Set the grind level to one level coarser.
See "Service and maintenance" - "Finer set-
ting of grind level".
The grinder is blocked. Contact your service partner.