Operation Manual
www.schaerer.com Installation and commissioning
BASCP_EN
V03 | 08.2012
16
DANGER!
Risk of electrocution!
Danger of electric shock!
It is essential that you comply with the following instructions:
• The phase must be fused at the ampere value specified on the serial plate.
• It must be possible to disconnect the device from the mains power supply at all poles.
• Never operate a device with a damaged power cord. Have a defective power cord or plug
replaced immediately by a qualified service technician.
• Schaerer AG recommends against using an extension cable. If, despite this, an extension
cable is used (minimum cross-section: 1.5 mm²), observe the manufacturer data for the
cable (operating instructions) and the locally applicable regulations.
• Route the power cord in such a way that it does not present a tripping hazard. Do not pull
the cord over corners or sharp edges, pinch it between objects or allow it to hang loosely
in the open. Do not position the cord over hot objects, and protect the cord from exposure
to oil and aggressive cleaning products.
• Never lift or pull the device by the power cord. Never pull the plug out of the socket by its
cord. Never touch the power cord or plug with wet hands. Never insert a wet plug into a
power socket.
Power requirements
We reserve the right to make technical changes.
* For special features, see the serial plate as of 2013. The specified values refer to the basic
model.
SCP
Mains Power requirements
Fuse protec-
tion (site
face)
Connecting
cable con-
ductor
cross-sec-
tion
1L, N, PE 220 – 240 V ~ 50/60 Hz 2000-2400 W 10 – 16 A
3 x 0.75 mm²
3 x 1 mm²
1L, N, PE 100 V ~ 50/60 Hz 1350 W 10 – 16 A
3 x 0.75 mm²
3 x 1 mm²
1L, N, PE 110 – 127 V ~ 50/60 Hz 1700 W 15 A 3 x 1.5 mm²
2L, PE 200 V 2~ 50/60 Hz 1800 W 15 A 3 x 1.5 mm²
*SCP Powerpack
Mains Power requirements
Fuse protec-
tion (site
face)
Connecting
cable con-
ductor
cross-sec-
tion
1L, N, PE 208 – 240 V ~ 50/60 Hz 5500-6500 W 25-30 A 3 x 2.5 mm²
2L, PE 208 – 240 V ~ 50/60 Hz 5500-6500 W 30 A
3 x 2.5 mm²
3 x 10 AWG