User manual

53
www.schaerer.com
User Manual SCF - EN
05.2008 / Version 06
Messages and Tips
Error
Display
Error Description Action
88 Boiler
overheating
Beverage dispenser temporarily blocked.
Check that mains tap is on or that the water tank is
filled and correctly inserted
If subsequently no OK:
Switch off coffee machine
Clean brewing unit
See Customer Care Chapter, Cleaning, Brewing unit
Switch on and try again
(Release follows when cooled down to normal temperature).
Switch off coffee machine, allow to cool and switch
on again
89 Boiler
heat‑up time fault
Switch machine off and on again
161 Brewer water fault
Between each of the following steps switch the machine off and on
again. If fault not remedied carry out the next step.
Check that main tap is on or water tank correctly
filled and inserted
Clean brewing unit
See Customer Care Chapter, Cleaning, Brewing unit
Set grind fineness one grade coarser
See Other Settings chapter
Reduce Quality
See Settings, Recipe
163 Warm rinse water
fault
Between each of the folloing steps switch the machine off and on
again. If fault not remedied carry out the next step.
Check that main tap on or water tank correctly
filled and inserted
Clean brewing unit
See Customer Care Chapter, Cleaning, Brewing unit
186 Steam boiler level
Outlet temporarily blocked.
Check that coffee grounds container correctly
inserted
Switch machine off and on again
188 Steam boiler
overheating
Outlet temporarily blocked.
After releasing check milk foam and steam outlet
Switch off machine, allow to cool and switch on
again
189 Steam boiler
heatup time
failure
Switch machine off and on again