Operation Manual
BASCJ_EN
V02 | 08.2012
9
www.schaerer.comProduct description
Technical data
We reserve the right to make technical changes.
* For special equipment, see serial plate. The values specified here apply to the basic equip-
ment.
** The A-weighted noise level (slow) and Lpa (impulse) at the workplace of the operating per-
sonnel is below 70 dB (A) for every operating mode.
Water filter for internal drinking water tank The water filter can be installed in the internal
drinking water tank.
Capacity: 200 l
Mains water supply The tank is filled via a water inlet outside of
the machine. This option can be retrofitted.
For detailed information, please contact your sales partner.
Example Option Description
Nominal power* 1700 – 2300 W
Operating temperature Steam boiler Hot water boiler
Minimum operating temperature (T min.): 130°C 86°C
Maximum operating temperature (T max.) 130°C 102°C
Overpressure Steam boiler Hot water boiler
Working overpressure 2.5 bar 16 bar
Permissible working overpressure (p max): 16 bar 16 bar
Test overpressure 24 bar 24 bar
Water tank capacity 2.2 l
Bean hopper capacity 250 g
Grounds container capacity 15 – 20 coffee grounds cakes
External dimensions
Width 305 mm
Height 400 mm
Depth 443 mm
Empty weight 16 kg
Permanent noise level** <70 dB (A)