Operation Manual

53
www.schaerer.com
User Manual SCF - EN
03.2010 / Edition 07
Messages and instructions
In many cases, this eliminates the malfunction and you
can continue working.
If this is not successful: Find the error message or error
code in the following list and follow the sequence of
actions indicated.
If this does not rectify the fault or if the error indicated is
not listed please call Schaerer Service.
Some messages lead to blocking of individual functions.
You will notice this by the fact that the beverage button
light goes out. The beverage buttons that are still
illuminated can continue to be used.
Your Schaerer Coffee Factory is provided with
a diagnostics program. Any errors that occur are shown
on the display. The errors listed may also be caused by
an interruption to the mains electricity supply.
If there is a current error or a message to the operator,
pad is displayed.
Touch the pad
Error number is displayed.
Error
display
Error
description
Action instruction
6 Brewing unit lockup
current /
Brewing unit stiff
Switch off the coffee machine
Cleaning the brewing unit
w C a r e w Cleaning the brewing unit
26
36
Right grinder
blocked
Left grinder
blocked
Switch off the coffee machine
Disconnect mains plug
Remove bean hopper
Turn grinder disk counter-clockwise using only
Multitool (square button) (see illustration).
Replace hopper
Switch on coffee machine
w C a r e w Product hopper cleaning
If this occurs frequently:
Set grinding degree one stage coarser
w Other settings w Set grinding degree