Operation Manual

www.schaerer.com Cleaning
34 / 50
Operating instructions / V07 / 08.2011
M. Schaerer Ltd. Cleaning instruction 06.2008 V07
Gewerbestrasse 15 QRCSCC BCL_w_EN
3302 Moosseedorf
Switzerland
info@schaerer.com www.schaerer.com Part number: 021561
Pull out the hose with the air valve.
Clean air valve with the supplied cleaning
tool.
Re-install the parts in reverse order.
Ensure that the air valve is con-
nected correctly on position
1
!
Close front door.
Move beverage outlet to the lowest posi-
tion.
Pull outlet cover out in the direction shown
by the arrow.
Hold the outlet with both hands.
Carefully pull outlet cup out in the direction
shown by the arrow.
Clean the outlet cover
1
and the outlet
cups
2
under warm, running water.
Re-assemble all the parts in the reverse or-
der (
6
-
5
) and place them back.
Open front door.
Spray commercial glass cleaner onto a pa-
per tissue and clean the Touch Screen (not
with pressure!).
Never spray the glass cleaner di-
rectly onto the Touch Screen!
Dry the Touch Screen with a paper tissue.
Close front door.
5 6
7
1 2
2
Follow hygiene regulations according to HACCP!
Extract from HACCP:
Never top up milk container. Always throw leftovers away.
Always clean the milk container before filling it with fresh milk.
Fill up with fresh milk, chilled to 3 5°C, just before restarting the machine.
Use pasteurized or ultra hightemperature treated (UHT) milk! Do not use raw milk! The milk must be homogonised!
If equipped, the refrigerator / cooling unit (optional) must be cleaned at least once a week!
4
1