Page 8-4 BASCC BC - 02.08 - V01
8.3 Serials Plates of Steam Generator and Instant Heater
Type DA HW HW
Excess operating pressure 2.5 bar 2.5 bar 2.5 bar
Maximum operating. pressure p max 12 bar 12 bar 12 bar
Test excess pressure 24 bar 24 bar 24 bar
Maximum op. temperature T max 192 ºC 192 ºC 192 ºC
Minimum op. temperature T min 10 ºC 10 ºC 10 ºC
Operating temperature 140 ºC 95 ºC 95 ºC
Water capacity Vol. 0.8 l 0.8 l 1.2 l
Constr. year: 20.. 20.. 20..
Manufacture number DA..... HW..... HW.....
Voltage U 230 VAC. 230 VAC. 230 VAC.
Frequency f 50/60 Hz 50/60 Hz 50/60 Hz
Capacity (Watts) P 3000 W 3000 W 2x3000 W
Design and testing according to SVTI and TÜV regulations.
8.4 Environmental Aspects
Packaging: The machines are delivered in recyclable cardboard boxes on reusable pallets.
Spare parts: Parts exchanged during a service are reconditioned as far as possible and used
again.
Cleaning agent Environmental protection!
If no recycling is possible, cleaning agents and their packaging must be disposed of in
line with local laws and regulations in accordance with the "HEALTH AND SAFETY
DATA SHEET."
Energy consumption The energy consumption corresponds to the technical state of the art at the time the
machine was developed.
Disposal: Environmental protection!
The machines must be disposed off correctly and in line with local laws and
regulations.