Technical data
www.schaerer.comInstallation & Commissioning
Programming manual / V01 / 02.2010
9 / 62
Power supply
Mains voltage tolerance 400 V (± 10 %) 200 – 220 V (± 10 %) mains break < 50 ms no functional
interruption
Protection IP 50
Model BCL
Model Power rating
Fuse (installa-
tion site)
Connection
cable conductor
cross-section
SCC BCL Europe
380-415V 3N~ 50/60Hz
8500-10100W
3 x 16A 5 x 1.5mm
2
3000-3400W
220-240V ~ 50Hz 5800-6900W
3 x 16A 5 x 1.5mm
2
1 x 30A 3 x 4mm
2
SCC BCL Korea 400V 3N~ 50/60Hz 10200W 3 x 16A 5 x 1.5mm
2
SCC BCL Japan,
Saudi-Arabia, Nor-
way-Net B
200-220V 3~ 50/60Hz
7400-8400W
2 x 30A 4 x 10AWG
5000-5700W
Model BC
Model Power rating
Fuse (installa-
tion site)
Connection
cable conductor
cross-section
SCC BC Europe
380-415V 3N~ 50/60Hz
8500-10100W
3 x 16A 5 x 1.5mm
2
3000-3400W
5800-6900W
220-240V ~ 50HZ
3000-3400W 1 x 16A 3 x 1.5mm
2
5800-6900W 1 x 30A 3 x 4mm
2
SCC BC Korea 400V 3N~ 50/60HZ 10200W 3 x 16A 5 x 1.5mm
2
SCC BC Japan,
Saudi-Arabia, Nor-
way-Net B
200-220V 3~ 50/60HZ
7400-8400W
2 x 30A 4 x 10AWG
5000-5700W
200-220V 2~ 50/60HZ 5000-5700W 2 x 16A 3 x 1.5mm
2
Model C
Model Power rating
Fuse (installa-
tion site)
Connection
cable conductor
cross-section
SCC C Europe 220-240V ~ 50Hz
3000-3400W 3 x 16A 5 x 1.5mm
2
5800-6900W 1 x 30A 3 x 4mm
2
SCC C Japan, Sau-
di-Arabia, Norway-
Net B
200-220V 3~ 50/60HZ
7400-8400W
2 x 30A 4 x 10AWG
5000-5700W
200-220V 2~ 50/60HZ 5000-5700W 2 x 16A 3 x 1.5mm
2
The device must be electrically connected according to all valid regulations (VDE 0100) as well as na-
tional stipulations. The type of power cable must be at least H05 RN-F. The voltage specied on the serial
plate must match the supply voltage at the installation location.
● The phase must be protected from short-circuits with the Ampere value mentioned on the serial plate!
All poles of the device must be able to be disconnected from the power supply. ●
Never operate a device with a faulty power cord. Have a defective power cord or plug replaced im- ●
mediately by a qualied service technician.
Schaerer Ltd. advises against the use of extension cables! If an extension cable must be used, ●
nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufacturer’s data
(instructions for use) and all local regulations.
Power cords must be connected in such a way that no one can trip over them. Do not pull the cords ●
over corners or sharp edges, pinch them between objects or allow them to hang loosely in a room.
Do not place cables over hot objects, and protect them from oil and aggressive cleaning agents.
Never lift or pull the device by its power cord. Never pull the plug out of the socket by its cord. ●
Never touch the power cord or plug with wet hands! Never insert a wet plug into a power socket!
CAUTION!
Risk of damage to
the machine!