Technical data
www.schaerer.comSafety notes
Programming manual / V01 / 02.2010
59 / 62
Risk of damage to the machine
● For water with a carbonate hardness of more than 5°dKH, a lime-scale lter should be connected; other-
wise the coffee maker could be damaged through lime-scale deposits.
For insurance reasons, always make sure that the main tap for the water supply (coffee maker with xed ●
water connection) is closed after operating hours have ended and that the main electrical switch has been
switched off or the power cord has been disconnected.
The device may not be operated if the water supply is blocked, otherwise the boilers cannot be relled and ●
the pump runs “dry”!
To prevent water damage in the event of a ruptured hose, it is recommended to (structurally) direct the ●
water supply through a water stop valve.
After extended down times (e.g. holidays), the coffee maker must be cleaned before being placed in op- ●
eration again.
Protect the coffee maker from weather conditions (frost, moisture, etc.). ●
Malfunctions may only be rectied by a qualied service technician! ●
Only use Schaerer Ltd. original spare parts! ●
In devices with a refrigerator, the power supply must never be completely interrupted, or the cooling func- ●
tion will not work.
In the event of noticeable damage or leaks, notify a qualied service representative approved by the man- ●
ufacturer and have faulty parts replaced and/or repaired!
Never spray the device with water or any other uid (e.g. steam cleaner)! ●
Never immerse the device in water or in any other uid! ●
When using caramelized coffee (aromatized coffee), the brew unit must be cleaned at least twice a day! ●
Never pour instant coffee into the slot! Only pour ground coffee into the slot! ●
If the coffee machine and/or auxiliary devices are transported at temperatures below 10°C, the coffee ●
machine and/or auxiliary devices must remain for 3 hours at room temperature before being connected to
a power supply and switched on. If this recommendation is not observed, there is a risk of short circuits or
damage to the electrical components as a result of condensation.
Always use the new hoses supplied with the machine (fresh-/drain water hose). Do not use old fresh- and ●
drain water hoses!
Hygiene
Before using the coffee maker for the rst time, carry out the cleaning program (refer to Operating instruc-
tions, chapter “Cleaning”).
Coffee, milk and other contents
Do not use any raw milk! Only use pasteurized milk or UHT milk! In all cases, the milk must be homog- ●
enized!
Only use pre-refrigerated milk with a maximum temperature of 5°C. If the milk is warmer than 5°C, an ●
optimal product cannot be dispensed..
For hygienic reasons, it is recommended to use milk directly from its original package whenever possible. ●
When using a milk container: never top up milk and always clean the container thoroughly before relling. ●
Do not ll containers with more coffee or milk than are required in one day. ●
It is recommended to dispose of any remaining milk at the end of the day (if the milk was in contact with ●
the milk tube).
Before opening milk packages, check them for damage. ●
Store coffee and products in a dry, cool and dark place. ●
Use the oldest products rst (“rst-in-rst-out” rule of thumb). ●
Use the products before their expiry date. ●
Always seal opened packages tightly so that their contents will remain fresh and protected from dirt. ●
Store coffee and ingredients separately from cleaning products. ●
Re-close the bean container lids immediately after adding beans! ●
CAUTION!
Machine at risk!