Technical data

www.schaerer.com10. Software upgrade
Programming manual / V01 / 02.2010
51 / 62
10. Software upgrade
Parameter / Menu Procedure Explanations & Remarks
10. Software upgrade
Upgrade process is started:
Please place SAVE-DATA card, to
backup the present conguration.
Cancel
Data successfully savedt
OK
Insert the SAVE DATA card to save all machine datas to
the card.
IMPORTANT REMARK:
Refer to technical information 012-09.
The conguration is saved.
- Use the serial cable to connect the
machine with the PC.
- Start Hexload.
Cancel
Start upgrade process:
Connect the PC with the machine using the serial cable.
Start Hexload.
Settings for Hexload:
Baudrate:
115200 (depending on Bootloader version) -
ComPort:
COM 1 (depending on PC conguration) -
Select the latest released software version.
Press “F9” to start the upgrade process.