Technical data

www.schaerer.com 4. System test / calibration
32 / 62
Programming manual / V01 / 02.2010
4. System test / calibration
Parameter / Menu Procedure Explanations & Remarks
4.1. Input / output test
ATTENTION: The main relay must always be activated! Enter the Input / Output test only after being asked to do so by technical sup-
port!
Input 0
Monit. valve 1
Activate the desired input by pressing the eld. Up to three inputs can be activated at the
same time.
White background = inactive
Black background = active
Output 23
Main relay 30V
Activate the desired output by pressing the eld. Up to three outputs can be activated at the
same time.
White background = inactive
Black background = active
4.2. Diagnosis screen
Software Celebration
Version 3.37 (7861)
Date April 20 2009 / 15:30
Bootloader 1.40
Data structure -
Machine number 0.00.000‘000
Installation number 0
Country codes 0
5V voltage 5.00 V
30V voltage 29.9 V
Self explanatory! REMARKS:
The diagnosis screen offers the possi-
bility to view various informations about
the machine.
Machines produced until 05.2009 (09xx
xxx‘xxx) are with Bootloader 1.13.
Machines produced from 05.2009 are
with Bootloader 1.40.
From Bootloader 1.40 the V-Drive
adapter must be installed (refer to tech-
nical information 002-09)!
Coffee boiler 98°C
Booster 109°C
Hot water boiler 99°C
Steam boiler 134°C
Refrigerator 3°C
LC-Display -
Over-temperature (Coffee) 0°C
Control timer (Coffee) 0.0 s
Coffee heater OFF
Hot water heater OFF
Steam heater OFF
Self explanatory!
4.3. Set pump pressure
Start process
Press “Start process” to start the pump pressure proc-
ess.
The pump is running in a closed system. The ;
valves open periodically to relieve the pressure in
the system.
Set the pump pressure to maximal 7.5-8 bar (0.75-0.8
MPa).
Under the following conditions the pump
pressure must be adjusted:
New installation of machine;
When changing location of installation;
Exchange of water pump;
At a preventive maintenance (min. 1 x
per year);
When the water pump is not working
correctly.
Stop (xx:xx)
Press “Stop (XX:XX)” to end the process.
After 2 minutes the process stops automatically. -