Technical data
www.schaerer.com1. General parameters
Programming manual / V01 / 02.2010
19 / 62
Parameter / Menu Procedure Explanations & Remarks
Level control with milk balance BCL
Enter the menu “System test / calibration” to set the “milk ●
empty” message.
Procedure:
Refer to page ► 34.
Machines produced until 12.2007; ●
Machine number: 0752 XXX‘XXX ●
Level control with sensor BCL
The “milk empty” message can not be adjusted. ●
Machines produced from 01.2008 ●
Machine number: 0801 XXX‘XXX ●
The “milk empty” message can not be adjusted. ●
Machines produced from 05.2009 ●
Machine number: 0905 XXX‘XXX ●
Level control with sensor for under counter milk system BC / C
2
1
Procedure:
Place the milk container with the desired “milk empty” ►
level into the refrigerator.
Turn the screw ►
1
until the LED
2
is illuminated green.
Explanation LED:
LED is green = milk is detected ●
LED ● not green = milk is not detected
Under counter milk pump unit:
Milk empty message Disable serving
Range: Disable serving, Warning
To block the machine or to generate a warning when the ►
milk empty level has reached.
Set on “Disable serving” for machines in ●
self-service operation!
Squeezer fridge active Disabled
Enable if the machine is equipped with the new rinsing ►
system.
IMPORTANT REMARK:
Parameter is only active with main ●
board revision 6!
Only possible for SCC BCL! ●
Refer to technical information 027-08. ●