Technical data

www.schaerer.com1. General parameters
Programming manual / V01 / 02.2010
17 / 62
Parameter / Menu Procedure Explanations & Remarks
Informations about brew motor versions 24V / 36V
Correct position (after initialising)
The installed and programmed brew motor version are
correct.
The brew unit is in it’s correct position
(“Home” position) after initialising.
Wrong position 1 (after initialising)
Installed brew motor version = 24V.
Programmed brew motor version = 36V.
The lower piston is moving to far up after ini-
tialising (motor to fast).
Wrong position 2 (after initialising)
Installed brew motor version = 36V.
Programmed brew motor version = 24V.
The lower piston is to low after initialising
(motor to slow).
Temperature display ºCelsius
Range: ºCelsius, ºFahrenheit
Set the temperature format.
Steam cup warmer Disabled
Enable or disable the steam cup heater.
Visible from software version V3.42
1.3. Calibrate grinders
ATTENTION: Only enable grinders which are physically installed on the machine
Grinder left Enabled
Enable or disable the left grinder.
Set parameter ► refer to page 7!
Grinder back Enabled
Enable or disable the back grinder.
Grinder right Enabled
Enable or disable the right grinder.
Grinder front Enabled
Enable or disable the front grinder.