Technical data
www.schaerer.com 1. General parameters
16 / 62
Programming manual / V01 / 02.2010
Parameter / Menu Procedure Explanations & Remarks
Connection 3 Phase (16A)
Range: 3 Phase 16A, 1 Phase 30A, 1 Phase 16A
Set the mains power connection according to the serial ►
plate.
IMPORTANT REMARK:
Check the serial plate before changing ●
the connection!
It is not allowed (under any circum- ●
stances) to modify the mains power
connection of the machine!
Mix operation (preselection) Enabled
Enable or disable the mixed operation (preselection). ► Block ● for machines in self-service op-
eration!
„Preselection“ must be enabled on the ●
beverage as well!
Buttons 2x-click Enabled
Enable if by a short double click (within 1 second) on the ►
beverage button serves a double product.
Block ● for machines in self-service op-
eration!
„Double product“ must be enabled on ●
the beverage as well!
Self-service Disabled
Enable or disable self-service operation. ► If enabled the functional buttons are not ●
visible in the ready for operation Touch-
screen.
Refer to cover back page for further in- ●
formation.
Switch off with the CHEF card Disabled
Enable if the machine is switched off with the CHEF ►
card.
–
Empty grounds container 60 coffee
Range: 0 - 100 coffee
Set the volume of the coffee grounds container. ►
Set to “0” for machines with under coun-
ter grounds disposal. The container is not
monitored any more! Inform customer to
empty the container daily!
Filter change X liter
Range: 0 - 60‘000 liter
Set the amount of litres until the lter has to be changed. ►
–
Service request by time
Range: by time, by (brew) cycles, disabled
Enable if the service request should be displayed on the ►
Touchscreen.
–
Service request after 12 month
Range: 0 - 24 month
Set the time, amount of month or brew cycles (depending ►
on the menu “Service request”) until the service request
is displayed on the Touchscreen.
–
Mains voltage 230 Volt
Attention: measure the mains voltage before setting!
Set the existing mains voltage (± 10 %). ►
This setting has an inuence on the boiler
heatings. If a beverage button is pressed,
the heating for the boiler starts immediately
for the programmed water quantity (time).
Boiler heating 3 kW
Range: 2.2 kW, 3 kW
Set the boiler heating performance. ►
Standard: ● 3 kW
Refer to serial plate! ●
Steam outlet Automatic (with button)
Range: Automatic (with button), Manual (with tap),
None
Set the steam output type. ►
Refer to „Assign external buttons“, on page
31.
Brewer rinsing None
Range: None, 15 min., 30 min., 45 Min., 60 min.
Set the interval for the automatic brewer rinsing. ►
Recommendation:
No brewer rinsing! ●
Brew process without coffee!
Version of control board Auto. (Rev. 3)
Range: Auto (Rev. 3), Rev. 3, Rev. 6
Version of the installed main board. ►
IMPORTANT REMARK:
Recognised automatically! Do not change!
Safety Switches Disabled
Disable:
For machines produced until 12.2007 (0752 XXX‘XXX). ►
Enable:
For machines produced until 01.2008 (0801 XXX‘XXX). ►
Refer to technical information 013-08.
Brewer motor 36 V
Range: 24 V, 36 V
Set the installed brew motor version. ►
Refer to technical information 040-08. ●
Further information about the brew mo- ●
tor version on page 17.