Operating instructions
www.schaerer.com Product description
8 / 56
Operating instructions / V07 / 01.2010
► All poles of the device must be able to be disconnected from the power supply.
► Never operate a device with a faulty power cord. Have a defective power cord or plug re-
placed immediately by a qualied service technician.
► Schaerer Ltd. advises against the use of extension cables! If an extension cable must be used,
nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufacturer’s
data (instructions for use) and all local regulations.
► Power cords must be connected in such a way that no one can trip over them. Do not pull
the cords over corners or sharp edges, pinch them between objects or allow them to hang
loosely in a room. Do not place cables over hot objects, and protect them from oil and ag-
gressive cleaning agents.
► Never lift or pull the device by its power cord. Never pull the plug out of the socket by its cord.
Never touch the power cord or plug with wet hands! Never insert a wet plug into a power
socket!
The phase must be protected from short-circuits with 16A / 30 A (Ampère)!
Model overview
The Schaerer Coffee Celebration BC and C models are both available with an optional under
counter milk system.
For more information please contact your local distributor.
Power supply
Model Power rating
Fuse
(installation
site)
Connection
cable conductor
cross-section
SCC BC Europe 380-415V 3NAC 50/60Hz
8500-10100W
3 x 16A 5 x 1.5mm
2
3000-3400W
5800-6900W
SCC C Europe
220-240V AC 50Hz
3000-3400W 1 x 16A 3 x 1.5mm
2
SCC BC + C
Europe
5800-6900W 1 x 30A 3 x 4mm
2
SCC BC Korea 400V 3NAC 50/60Hz 10200W 3 x 16A 5 x 1.5mm
2
SCC BC Japan,
Saudi Arabia,
Norwegen-Netz B
200-220V 3AC 50/60Hz
7400-8400W
2 x 30A 4 x 10AWG
SCC C Japan,
Saudi Arabia,
Norway mains B
5000-5700W
SCC BC + C
Japan, Saudi
Arabia, Norway
mains B
200-220V 2AC 50/60Hz 5000-5700W 2 x 16A 3 x 1.5mm
2
The device must be electrically connected according to all valid regulations (VDE 0100) as well as
national stipulations. Design of network implementation line, at least H05 VV-F, harmonized. The
voltage specied on the serial plate must match the supply voltage at the installation location.