Operating instructions
www.schaerer.com Safety notes
56 / 56
Operating instructions / V07 / 01.2010
Intended use
The Schaerer Coffee Celebration has been designed to dispense coffee beverages and/or milk
beverages in different versions – in cups or coffeepots. Additionally, the unit can supply steam for
heating up milk and/or hot water. This unit is designed for industrial and commercial use. The unit
may be placed in self-service areas if attended to by trained personnel.
Use of this equipment is subject to the “General Terms and Conditions” of Schaerer Ltd. and these
operating instructions. In legal terms, any other use is not an intended use. The manufacturer ac-
cepts no liability for damage resulting from unintended use.
The Schaerer Coffee Celebration may not under any circumstances be used to heat up or dis-
pense any other liquids than coffee, hot water (for beverages or cleaning) or milk (cooled, pas-
teurised, homogenised, UHT).
Liability
No responsibility will be taken for warranty or liability claims in the event of personal injury or mate-
rial damage as a result any or all of the following causes.
Cleaning:
► Thoroughly wash and disinfect hands before and after cleaning the machine!
► Clean the machine daily once beverage output has been completed.
► For daily and weekly cleaning, follow the steps in the Operating instructions (chapter "Clean-
ing") and on the cleaning card.
► Never mix cleaning products!
► Never use abrasive substances or cleaning tools made of metal!
► Do not touch parts that come into contact with beverages (during or before output) after
they have been cleaned.
► Follow the dosage and safety instructions on the cleaning product! Information about clean-
ing products can be found in the Operating instructions, chapter "Appendix".
► If the machine is equiped with a the refrigerator / cooling unit (optional) this must be cleaned
at least once a week!
► Improper use of the device.
► Improper installation, commissioning, operation and/or servicing of the device and its corre-
sponding options.
► Non-observance of recommended maintenance intervals.
► Operation of the device with defective safety devices, non-functioning safety devices or im-
properly attached protective devices.
► Non-observance of safety notes in the Operating instructions with respect to storing, installing,
commissioning, operating and servicing the machine.
► Operation of the device in less than optimal condition.
► Improperly conducted repairs.
► If replacement / spare parts used are not original spare parts by Schaerer Ltd.;
► If cleaning agents other than those recommended by Schaerer Ltd. have been used;
► Emergencies or failures due to the effects of a foreign body, accident or vandalism as well as acts
of God.
► Insertion of objects into the device as well as opening of the housing.
► Schaerer Ltd. must be notied in writing immediately of any material aws!
► The device must be serviced every 12 months or after 70'000 products have been dispensed,
which ever is earlier.
Safety-relevant parts such as safety valves, safety thermostats, boilers, etc. must never be re-
paired under any circumstances. They must be replaced as follows:
► Safety valves every 12 months
► Boiler (steam boiler, ow heater) every 60 months
The manufacturer only accepts liability or honnors warranty claims provided that all specied
maintenance and service intervals have been abserved and that only original spare parts sup-
plied by the manufacturer or an approved authorized supplier have been used.