Inverters
Frequency Designation
Inverters
AC / AC Inverters with 3-phase output from 1.5kVA to 45kVA
19“ sub-rack / approx. 27 kg
*)
with wall plate / approx. 31 kg
*)
19
"
6U
350 mm
500 mm
400 mm
310 mm
19“ Plug-in module / approx. 32 kg with wall plate / approx. 36 kg
19"
6U
360 mm
500 mm
400 mm
310 m
m
approx. 23 kg / 3.4 kVA
Size A
Size G
Size T1 - T3 Size T4
19"
6U
36
0
mm
500
m
m
600 mm
330
m
m
Size C Size D
19"
6U
510 mm
500 mm
600 mm
3
3
0 m
m
19“ sub-rack / approx. 40 kg
*)
with wall plate / approx. 45 kg
*)
19“ sub-rack / approx. 24 kg
**)
with wall plate / 55/65 kg
*)
Trans -
former
ØH
Weight
in kg
Power
in kVA
in mm
T1
T2
T3
190
205
243
75
85
85
8.6
12
15
1.4
2
3
Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required
.
1
9
"
7U
4
6
0
m
m
5
0
0
m
m
800 mm
3
7
0
m
m
Size E Size F
19
"
6U
4
60 mm
500 mm
800 mm
370 mm
19“ sub-rack / approx. 27 kg
**)
with wall plate / approx. 70/80kg
*)
19“ sub-rack / approx. 28 kg
**)
with wall plate / approx. 104 kg
*)
Attention:
For 3-phase system
3 modules are required.
192 mm
200 mm
176 mm
H
Ø
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
W
H
D
Size T5 - T8
Trans -
former
HWD
Weight
in kg
Power
in kVA
in mm
T5
T6
T7
T8
390
450
450
500
240
280
280
320
233
253
283
280
33
50
66
110
5
8
12
15
Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required
.
Wall mount version
W
H
D
Size T5
Trans -
former
HWD
Weight
in kg
Power
in kVA
in mm
T5 335 230 210 33 5
Transformers refer to 50/60 Hz at the output.Other frequencies
or tropical insulation may change size and weight.
Attention: For 3-phase system 3 transformers are required
.
standing version
Transformer refers to 50/60 Hz at the output.
Other frequencies or tropical insulation may
change size and weight.
Attention: For 3-phase system 3 transformers
are required
.
Series IV Switch mode inverters with output transformers for isolation and voltage transformation
AC output
AC input
3 x Inverter
with input
rectifier
3-phase
3 x Transformer
1 or 3-ph.
.1
.2
.3
.4
.41
.5
.51
.6
.61
.7
.8
40 - 400 Hz adjustable / programmable
45 - 65 Hz adjustable / programmable
any fixed frequency between 40 - 400 Hz
400 Hz
synchronized with 400 Hz mains
50 Hz
synchronized with 50 Hz mains
60 Hz
synchronized with 60 Hz mains
50/60 Hz switchable
800 Hz
Input VAC
1-Phase
Output
kVA
Size
Input VAC
1-Phase
Input VAC
3-Phase
Output
kVA
Size
Cooling
Output
VAC
line-to-line
115
± 20 %
230
+ 15 %
– 20 %
3x200
+ 15 %
– 20 %
3x400
+ 15 %
– 20 %
3x480
+ 10 %
– 15 %
IV 5566
IV 5666
IV 5766
IV 5866
IV 6266
IV 6466
1.5
3
3.6
6
9
15
A
C
D+T1
E + T2
G+T3
G+T5
IV 5586
IV 5686
IV 5786
IV 5886
IV 6286
IV 6486
IV 5566 V
IV 5666 V
IV 5766 V
IV 5866 V
IV 6266 V
IV 6466 V
IV 5686 V
IV 5786 V
IV 5886 V
IV 5886 VF
IV 6286 V
IV 6486 V
IV 6686 V
IV 6886 V
IV 5796 V
IV 5896 V
IV 5896 VF
IV 6296 V
IV 6496 V
IV 6696 V
IV 6896 V
1.8
3.6
5.4
7.5
10
15
24
36
45
A
C
D + T2
E + T3
F + T4
G + T5
G + T6
G + T7
G + T8
3 x 200
IV 5568
IV 5668
IV 5768
IV 5868
IV 6268
IV 6468
1.5
3
3.6
6
9
15
A
C
D+T1
E + T2
G+T3
G+T5
IV 5588
IV 5688
IV 5788
IV 5888
IV 6288
IV 6488
IV 5568 V
IV 5668 V
IV 5768 V
IV 5868 V
IV 6268 V
IV 6468 V
IV 5688 V
IV 5788 V
IV 5888 V
IV 5888 VF
IV 6288 V
IV 6488 V
IV 6688 V
IV 6888 V
IV 5798 V
IV 5898 V
IV 5898 VF
IV 6298 V
IV 6498 V
IV 6698 V
IV 6898 V
1.8
3.6
5.4
7.5
10
15
24
36
45
A
C
D + T2
E + T3
F + T4
G + T5
G + T6
G + T7
G + T8
3 x 400
IV 5569
IV 5669
IV 5769
IV 5869
IV 6269
IV 6469
1.5
3
3.6
6
9
15
A
C
D+T1
E + T2
G+T3
G+T5
IV 5589
IV 5689
IV 5789
IV 5889
IV 6289
IV 6489
IV 5569 V
IV 5669 V
IV 5769 V
IV 5869 V
IV 6269 V
IV 6469 V
IV 5689 V
IV 5789 V
IV 5889 V
IV 5889 VF
IV 6289 V
IV 6489 V
IV 6689 V
IV 6889 V
IV 5799 V
IV 5899 V
IV 5899 VF
IV 6299 V
IV 6499 V
IV 6699 V
IV 6899 V
1.8
3.6
5.4
7.5
10
15
24
36
45
A
C
D + T2
E + T3
F + T4
G + T5
G + T6
G + T7
G + T8
3 x 480
= natural convection = incl. temperature controlled fans
IV 5
666
3
C
IV 5686
IV 5666 V IV 5686 V
3
.
6
C
IV 6266
9
G+T3
IV
6
2
86
IV
6
2
66
V
IV
6286
V
IV
6296
V
15
G
+
T5
IV
6686
V
IV 6886 V
IV
6696
V
IV 6896 V
36
45
G
+
T7
G
T8
IV 55
68
1
.
5
A
IV 5588
IV
5568
V
1
.8
A
IV
5888
VF
IV
5898
VF
10
F
+ T
4
IV
6
4
68
15
G
+T
5
IV
6
4
88
IV
6
4
68
V
IV
6
4
88
V
IV
6
4
98
V
24
G
+
T6
IV
6888
V
IV
6898
V
45
G
+
T8
IV 5869
6
E
+
T2
IV 5889
IV
5869
V IV
5889
V
IV
5899
V
7
.
5
E
+
T
3
IV
6
2
69
9
G
+T
3
IV 6289
IV
6
2
69
V
IV
6289
V
IV
6
2
99
V
15
G
+
T
5
IV 5866
6
E
+
T2
IV 5886
IV
5866
V IV
5886
V
IV 5896 V
7
.
5
E
+
T3
IV 57
68
3
.
6
D+T1
IV 5788
IV
5
7
68
V IV
5
7
88
V
IV 57
98
V
5
.4
D
+
T2
IV 5
669
3
C
IV
5689
IV
5669
V IV
5689
V
3
.
6
C
IV
6689
V
IV
6699
V
3
6
G
+
T
7
*)
transformers internal
**)
transformers external