Manual
www.schaeferpower.de
Low Power Low Power
DC / DC Converters
DC
in
DC
out
Battery Chargers
AC
in
DC
out
Battery
Series specific information
AC / DC Power Supplies
AC
in
DC
out
Series C / B 4800
6U
56TE
6U
306 mm
280/320* mm
360/450* mm
309 mm
2.5 kW 3.5 kW 5 kW 5 kW
Input VDC
Cooling
Output VDC
10 –16
2)
VDC
Output
Amps
20 – 32
2)
VDC
Output
Amps
40 – 64
VDC
50 – 80
VDC
Output
Amps
80 –160
VDC
160 – 320
VDC
320 – 380
1)
VDC
320 – 640
2)
VDC
450 – 800
2)
VDC
Output
Amps
Adj. Range
C 4802
C 4803
C 4804
C 4805
C 4809
C 4806
C 4807
C 4807 J
C 4808
C 4808 J
136
116
92
80
44
36
20
12
10
6
C 4822
C 4823
C 4824
C 4825
C 4829
C 4826
C 4827
C 4827 J
C 4828
C 4828 J
190
160
120
100
60
50
26
14
14
7
C 4832
C 4833
C 4834
C 4835
C 4839
C 4836
C 4837
C 4837 J
C 4838
C 4838 J
C 4842
C 4843
C 4844
C 4845
C 4849
C 4846
C 4847
C 4847 J
C 4848
C 4848 J
240
2)
200
2)
150
130
76
62
36
20
20
10
C 4852
C 4853
C 4854
C 4855
C 4859
C 4856
C 4857
C 4857 J
C 4858
C 4858 J
C 4872
C 4873
C 4874
C 4875
C 4879
C 4876
C 4877
C 4877 J
C 4878
C 4878 J
C 4882 Z
C 4883 Z
C 4884 Z
C 4885 Z
C 4889 Z
C 4886 Z
C 4887 Z
C 4887 ZJ
C 4888 Z
C 4888 ZJ
C 4872 G
C 4873 G
C 4874 G
C 4875 G
C 4879 G
C 4876 G
C 4877 G
C 4877 GJ
C 4878 G
C 4878 GJ
C 4872 K
C 4873 K
C 4874 K
C 4875 K
C 4879 K
C 4876 K
C 4877 K
C 4877 KJ
C 4878 K
C 4878 KJ
260
2)
220
2)
160
2)
140
80
66
40
20
20
10
12
15
24
28
48
60
110
200
220
400
11 – 13
14 – 16
23 – 26
26 – 30
45 – 55
58 – 68
100 – 130
190 – 200
200 – 250
380 – 400
4 kW 5 kW
Input VAC, 1-Phase Input VAC, 3-Phase
Output Amps
Cooling
Output VDC
115
2)
± 20 %
Output
Amps
230
+ 15 %
– 20 %
3x200
+ 15 %
– 20 %
3x400
+ 15 %
– 20 %
3x480
+ 10 %
– 15 %
Adj. Range
C 4862
C 4863
C 4864
C 4865
C 4869
C 4866
C 4867
C 4867 J
C 4868
C 4868 J
260
220
150
130
72
60
30
16
16
8
C 4882
C 4883
C 4884
C 4885
C 4889
C 4886
C 4887
C 4887 J
C 4888
C 4888 J
C 4862 V
C 4863 V
C 4864 V
C 4865 V
C 4869 V
C 4866 V
C 4867 V
C 4867 VJ
C 4868 V
C 4868 VJ
C 4882 V
C 4883 V
C 4884 V
C 4885 V
C 4889 V
C 4886 V
C 4887 V
C 4887 VJ
C 4888 V
C 4888 VJ
C 4892 V
C 4893 V
C 4894 V
C 4895 V
C 4899 V
C 4896 V
C 4897 V
C 4897 VJ
C 4898 V
C 4898 VJ
260
2)
220
2)
160
2)
140
80
66
40
20
20
10
12
15
24
28
48
60
110
200
220
400
11 – 13
14 – 16
23 – 26
26 – 30
45 – 55
58 – 68
1
00
–
1
30
190 – 200
200 – 250
380 – 400
4 kW 5 kW
Input VAC, 1-Phase Input VAC, 3-Phase
Output Amps
Cooling
Output VDC
115
2)
± 20 %
Output
Amps
230
+ 15 %
– 20 %
3x200
+ 15 %
– 20 %
3x400
+ 15 %
– 20 %
3x480
+ 10 %
– 15 %
Nom.
Battery
Voltage
Range
B 4861
B 4862
B 4864
B 4866
B 4867
B 4868
220
122
62
50
28
14
B 4881
B 4882
B 4884
B 4886
B 4887
B 4888
B 4861 V
B 4862 V
B 4864 V
B 4866 V
B 4867 V
B 4868 V
B 4881 V
B 4882 V
B 4884 V
B 4886 V
B 4887 V
B 4888 V
B 4891 V
B 4892 V
B 4894 V
B 4896 V
B 4897 V
B 4898 V
220
2)
140
70
60
34
18
12
24
48
60
110
220
12 –
16
24 –
32
48 –
64
60 –
80
110 –
145
220 –
290
C
4
803
1
16
C
4
8
2
3
160
C
4
833
C
4843
200
2)
C
4
853
C 4873
C
4
883
Z
C
4
8
7
3
G
C
4
8
7
3
K
220
2)
15
1
4
–
1
6
C 4805
80
C
4
8
2
5
100
C
4
835
C
4845
1
30
C
4
855
C
4
8
75
C
4
885
Z
C
4
8
75
G
C
4
8
7
5
K
1
4
0
2
8
26
–
30
C
4
806
36
C 4826
50
C
4
836
C
4
8
4
6
6
2
C 4856
C
4
8
7
6
C 4886 Z
C
4
8
7
6
G
C
4
8
7
6
K
66
60
58
–
68
C 4807
J
1
2
C 4827
J
14
C 4837
J
C
4
8
47
J
2
0
C
4
8
57
J
C 4877
J
C 4887 Z
J
C 4877 G
J
C 4877 K
J
2
0
200
1
90
–
200
C
4
808
J
6
C
4
828
J
7
C
4
838
J
C
4848
J
1
0
C 4858
J
C
4
8
7
8
J
C 4888 ZJ
C 4878 G
J
C 4878 K
J
1
0
4
00
380
–
400
C
4
863
22
0
C
4
883
C
4863 V
C
4
883
V
C
4
893
V
2
2
0
2)
1
5
1
4
–
1
6
C
4
865
130
C
4
885
C
4
865
V
C
4885 V
C
4
895
V
14
0
2
8
26
–
30
C
4
866
60
C 4886
C
4
866
V
C
4
886
V
C
4
896
V
66
60
58
–
68
C 4867
J
16
C 4887 J
C
4867 V
J
C
4887 V
J
C 4897 V
J
20
2
00
1
90
–
2
00
C 4868 J
8
C 4888
J
C
4868 V
J
C
4
888
VJ
C 4898 VJ
1
0
4
00
380
–
4
00
B 4
862
1
22
B 4
88
2
B 4
862
V
B 4
882
V
B
4
892
V
1
4
0
2
4
24
–
32
B 4
866
50
B 4
886
B 4
866
V
B 4
886
V
B
4
896
V
60
60
60
–
80
B 4
868
14
B 4
888
B 4
868
V
B 4
888
V
B
4
898
V
18
2
2
0
22
0
–
290
ZVS topology
ZVS topology
ZVS topology
Eurocassette
(pluggable module for 19“ sub-rack)
Standard
Optional
*) applicable to models >= 150 A input or output current
Wall mount approx. 19 kg/ *) 22 kg
General
■
Thermal shutdown with auto restart
■
Option “rco” for ZVS-modules available (see p.118)
1)
Input supply from PFC also suitable
2)
Suited for wall-mount, alternatives upon request
= increased air flow recommended
Input
■
No-load input power: 15W typical
■
Switch-on time: 1 - 2s
■
Inrush current: 230V AC and 3-phase input:
limited by thermistor
■
Hold-up time for AC input: 5ms typical
@ nominal input voltage
Output
■
Response time to ±1 %: 5 - 10ms
■
Turn-on rise time: Soft-start,
100-300ms typical
■
OVP without restart for ZVS