Maintenance
WARNING
ELECTRICAL SHOCK
HAZARD
• Serious injury or death is possible.
• Disconnect from electrical supply
before performing any maintenance
operations.
NOZZLES
The fog or spray pattern exiting from the nozzles should
have an even cone shape. If this is not the case, the nozzle
should be cleaned or replaced. Nozzle function should be
checked regularly to assure best misting and evaporation
performance.
To clean or replace a nozzle:
1. Disconnect the unit from electrical supply.
2. Unscrew and remove the nozzle.
3. Soak in vinegar, rinse in water OR replace with new
nozzle.
4. Flush the water line to the mist hub before replacing
nozzle.
5. Screw the nozzle into the mist hub by hand.
NO TOOLS SHOULD BE USED TO TIGHTEN
THE NOZZLE.
FILTER
Filter maintenance requirements will vary with changing
water conditions. The filter should be inspected frequently
and changed as needed. A dirty filter will restrict water
flow to the pump and can cause permanent damage.
SYSTEM DRAIN / STORAGE
When it is time to store the VersaMist® or take it out of
use for more than a few days, it is strongly recommended
that the water be drained from the system to prevent
calcification problems and the formation of algae. Be sure
to empty the cooler or tank and allow it to air dry.
Clean the unit with a mild anti-bacterial solution regularly.
Replacement Parts
REPLACEMENT PARTS
P/N DESCRIPTION
TG18-3WX 18" circulation fan
MK-BRASSPLUG Misting plug
BN12 Brass replacement nozzle 0.012
TS3P Three-position toggle switch
PVM-PUMP Shurflo pump
PVM-TIPSWITCH Tip switch
PVM18-KNOB Knob, metric
MISTHUB2 Mist disk
C2500GFCI 25 ft power cord with GFCI
0WHEEL6X134R Rubber wheel, 6" x 1-3/4" (for mobile tank)