User Manual
SAFETY INFORMATION
Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this
information intact and easy to read at all times. Replace missing or damaged safety decals immediately. The diagram below shows the proper location
of the safety decals as shipped from the factory.
Using the equipment for purposes other than specified in this manual may cause personal injury and/or damage to the equipment.
SAFETY ALERT SYMBOL
This is a safety alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. This equipment is
designed to be installed and operated as safely as possible; however, hazards do exist.
Signal Words are used in conjunction with the safety alert symbol to identify the severity of the warning.
CAUTION indicates an imminently hazardous situation, which, if not avoided, COULD cause damage to your equipment or equipment failure.
WARNING indicates a potentially hazardous situation, which, if not avoided, COULD result in death or serious injury.
SAFETY RECOMMENDATIONS - READ AND SAVE THESE INSTRUCTIONS!
This is an electric device with moving components. There is the possibility of fire, electric shock or injury to persons. Ensure all
the safety recommendations are adhered to in order to minimize this risk.
PLEASE NOTE
Minimum inlet pressure is 10 PSI; maximum inlet pressure is 100 PSI.
Never leave unit unattended while in operation.
SPECIFICATIONS
• Height and Width 33" x 33" wide x 54" high (with casters and directional spout)
• Shipping Weight 225 pounds
• Blower double-inlet centrifugal
• Motor 1 Hp, 115V, 2 speed, 60 Hz
• Pump Filter washable polyethylene filter
• Pump Discharge Filter 480 micron stainless steel
• Reservoir Capacity 24 gallons
• Pump submersible vane type, 280 gallons per hour
• Housing high impact ABS plastic with UV protection
• Evaporation Media chemically treated cellulose paper
• Optional Water Supply standard 3/4" hose connection (garden hose size)
WARNING!
Interference with the oscillating spout while the unit is
operating, or manually directing the oscillating spout, will
cause damage to the gear motor. Keep oscillating path
clear of obstructions.
Start Unit -Turn water pump on 5-10 minutes before running blower
to wet evaporative cooling pads.
Shut Down -Turn pump off and run only blower until evaporative
cooling pads are dry. This prolongs the life of the pads.
WARRANTY- VOID IF YOU RUN THE PUMP WITHOUT WATER.
CAUTION - ALWAYS TURN OFF AT SWITCH AND DISCONNECT
POWER BEFORE REMOVING EVAPORATIVE COOLING PADS FOR
CLEANING OR INTERNAL MAINTENANCE.
CLEANING - Clean pads a minimum of once every two weeks.
Remove pads from unit and clean with garden hose only.
DO NOT use chemicals or high pressure hose.
Actual WayCool may vary slightly from unit shown here.Actual WayCool may vary slightly from unit shown here.
©2020 Schaefer®. All Rights Reserved. Portable Evaporative Cooler Operators Manual3