Instructions

SCH.E.I.D.LEnergyController
Page23of40
InstallationManualDataLogger
EN
Copyright
Theinstallationandoperating
instructionsareprotectedby
copyright.Reproductioneveninpart
isonlypermittedwiththeexplicit
permissionofthemanufacturer.
Inaheatstoragethethermal
energyorchargingpoweris
obviouslydisplayedincorrectly.1
kWh=1°Cincreaseintemperature
of1000litersofwatershowsasa
roughestimateothervalues
Thevolumeofthebufferisset
incorrectly.Thebuffertemperature
probewillbedeliveredwitha
defaultsettingforthe1000litersof
storage
Determinethevolumeofthe
installedheatstorage
Selectatthecontrollerunder
Settings>Buffer,your´sandenter
under"volume"thesizeofthe
installedbuffer
AnS0meteradapterindicates
obviouslyincorrectvalues.The
countsinthedisplayonthemeter
andjnthecontrollerincreasesin
differentrates
Theweightingofthepulsesisset
incorrectly.Theadapterwillbe
deliveredwithadefaultsettingof
1000pulses/kWhforEltakometer
Determinethepulses/kWhoutof
yourmetersdatasheet
Selectatthecontrollerunder
Settings>Meter,your´sandenter
under"weight"thevalueofyour
meter
Problem Cause Rectification
Troubleshooting
Limitationofliability
Theproductcorrespondstothe
currentstateoftheart.The
manufacturerassumesno
responsibilityfordamagecauseddue
toimproperuse,ownrepairs,ourown
otherchangestotheproductorof
unauthorizedspareparts.