Instructions

SCH.E.I.D.LEnergyController
Page20of40
InstallationManualDataLogger
EN
Buffertemperaturesensor3way
forhotwatertank
Length:2.5m,for2mhighbuffer
OrderCode:4260376260071
Theoptionalmultisensorallowspre
cisemonitoringofheatstoringe.g.for
drinkingwater,Solarstratifiedstorage
tankorincogenerationplants.The
stratificationisdetectedbythreesen
sorsthatarepluggedtogetherviaa
cable.Thankstothemagneticattach
menttothetank,thesensorsareea
sytoinstall.
Isrepresentedwiththetemperatures
ofthebufferlayer,theenergycontai
nedinkWh,andthecharge/dischar
gepowerinkW.
Sincethebufferisthecentralcompo
nentofmodernregulatedheatingin
stallations,storagelossesandlosses
inthesystemcanbefoundquickly.
1
Mechanicallyfasten
Buffertemperaturesensor
2
Connectthebuffertemperaturesensor
2.1 Putonthebuffertemperature
sensortothecontroller,ifne
cessarybehindothersensors
1.1 Bastethemagneticsensorat
thetop(withflags),centerand
bottomdirectlyonthesteel
tankunderinsulation
3
Instrumentsdisplay
3.1 Theinstrumentsofpower,
energyandtemperatures
appearinthedashboard
3.2 InSettings→Datapoints→
Buffer,setthevolumeand
temperatures
Accessories