User guide
24 CAT5/5e KVM Extender Range
Other Remote Configuration & Operation Options
Scroll Lock Function
Standard and Serial SDLink Remote Units redefine the function of the Scroll
Lock key for system commands.
Press the Scroll Lock key to reset the keyboard and mouse. You may need to do
this if a hot-plugged keyboard or mouse does not initialize correctly.
You can restore normal Scroll Lock activity by setting switch 4 on the SW1
DIP switch block to OFF (see Figure 13). If you do this, and then need to reset
a console’s keyboard and mouse, you will need to re-power the Remote Unit.
This also disables Private Mode operation in dual access systems (see page 27).
Power Mouse K’board Video
RJ45 Peak EQ
DIP Switch settings
OFF ON
Private Mode Video Disable YES NO
SUN versions: disables private mode
Inactivity Timeout Period 15s 2s
Console Switch Keyboard or Mouse Keyboard Only
Scroll Lock Function Normal Private Mode/
PS/2 versions only K’board/Mouse Reset
SUN versions - not used Mouse Recovery
Figure 13 Remote Unit DIP switches:
Switches 1, 2 and 3 control the implementation of Private mode and dual
access functions on the Local Unit (see page 27).
SW1 DIP
switches