Owner's manual

ECUsimâ„¢ 5100 User Guide 7
2.2 Back Panel
1. PIM Select switch
2. USB connector
3. Diagnostic Link Connector (DLC)
4. Configuration DIP switch
a. PIM ALL. Down position: makes all three PIMs active at the
same time. Up position: PIM selection is controlled by the
PIM Select switch
b. 5BAUD/FAST. Selects the type of initialization for
ISO 14230-4. Down: 5 baud init, up: fast init.
c. 11/29 BIT. Selects the CAN frame ID type. Down: 11-bit, up:
29-bit.
d. 250K/500K. Selects the CAN baud rate. Down: 250 kbps, up:
500 kbps.
5. Power jack (12 VDC)
Use only the provided power supply to power the simulator.
Using a different power supply may cause permanent damage
which is not covered under the warranty.