User’s Manual VEGA Area Imager V-1020/V-1020BT Handheld Bar code Scanner
EMEA SCANTECH-ID BV Nijverheidsweg Noord 60-34 3812 PM Amersfoort The Netherlands Tel:+31-33-4698400 Fax:+31-33-4650615 E-mail:info@scantech-id.com www.scantech-id.com HEAD QUARTER CHAMPTEK INCORPORATED 5/F, No.2 Alley 2, Shih-Wei Lane, Chung Cheng Rd., Hsin Tien City,Taipei 231, Taiwan Tel:+886-2-2219-2385 Fax:+886-2-2219-2387 E-mail:sales@champtek.com www.champtek.com China CHAMPTEK INCORPORATED #901, No. 39, Wuzhong Rd.
1 User’s Installation and Configuration Manual Scantech-ID VEGA
2 Copyright © 2009, Scantech-ID BV. This manual is copyrighted, with all rights reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic medium or machine readable form without prior written consent of Scantech-ID BV. Limited Warranty Under all circumstances this manual should be read attentively, before installing and/or using the product.
Scantech-ID Table of contents Table of Contents ...................................................................................... 3 Introduction................................................................................................ 7 Chapter 1............................................................................ Product Safety 9 1.1 Safety & Caution .............................................................................10 1.2 FCC Warning ......................................
4 Chapter 6 .............................................................. Configuring the VEGA 31 6.1 Preface ........................................................................................... 32 6.2 Factory Default Setting ................................................................... 34 Chapter 7 ................................................................ Programming Codes 35 7.1 Return to Default............................................................................. 36 7.
Scantech-ID 7.24 Matrix 2 of 5 Settings.......................................................................91 7.25 MaxiCode Settings ..........................................................................92 7.26 MicroPDF417 Settings.....................................................................93 7.27 MSI code Settings ...........................................................................94 7.28 PDF417 Settings ......................................................................
6 Appendices ............................................................................................ 122 A Decimal Value Table .......................................................................... 123 B ASCII Table ....................................................................................... 124 C Readable Symbologies ...................................................................... 125 D Technical Specifications.....................................................................
Scantech-ID Introduction VEGA is a cutting-edge gun-type barcode scanner which is designed specifically for retail market. To the brand new series of VEGA, we add on more user-friendly functions with detachable cable that makes it more easily to be operated by the customers. Speaking of the performance, this scanner supports middle to long range operation.
8 Chapter 1 Product Safety
Scantech-ID 1.1 SAFETY & CAUTION 1. Please read the following safety statement carefully. 2. Please preserve this user manual for reference sometime. 3. Before cleaning the VEGA, the users must cut off all AC power. Do not use liquid or spray type of detersive to clean the VEGA. Please use dampish cotton cloth to clean the VEGA. The outlet must set nearby the VEGA for connecting power easily. Keep the VEGA dry to avoid short circuit.
10 General Description 1.2 FCC WARNING This equipment complies with the requirements in Part 15 of FCC. Any operation must comply with the conditions below: (a) The equipment will not cause any severe interference. (b) The equipment can avoid any interference from environment. Statement: This product is classified as A class product. In environment this product may cause some interference. In this situation the user may do something to avoid interference.
Scantech-ID 1.3 SCANNER LABELLING Model Name Serial Number Model Name: VEGA V-1020 Area Imager VEGA V-1020BT Area Imager Bluetooth Serial Number: Product Serial No. (VA……..) See Appendix F for more information in detail.
12 General Description Chapter 2 General Description
Scantech-ID 2.1 USE OF THE VEGA The VEGA is very ergonomic and modern designed and very user friendly. It can be connected to your POS or Host system trough a RS232 cable, KBW cable, USB cable or with Bluetooth wireless. To read a bar code, you simply press the red trigger button and aim the beam to the bar code. But you need to position the beam so that it falls across all bars in the 1D barcodes. You will hear one beep and the green LED indicator will lights on after scan successfully.
14 Chapter 3 Installation of the VEGA V-1020
Scantech-ID 3.1 V-1020 UNPACKING Unpack the VEGA as follows: 1. Take the VEGA and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered. Standard Shipment Package a. VEGA Area imager handheld bar code scanner b. Power Adaptor if apply c. User Manual d. Communication Cable e. Stand f. Transparent Cover Plate 4. Visually inspect the VEGA and accessories for any evidence of physical damage. 5.
16 Installation of the VEGA V-1010 3.2 V-1020 MOUNTING Once you have unpacked all components, you can start installing the VEGA. Installing the VEGA is divided in different steps: 1. Connect the VEGA to the supplied communication cable (RJ45 side). 2. Connect the VEGA communication cable to the POS or Host system. 3. Connect the Power supply (if needed) to Power cable inlet. 4. Plug the power supply into the AC outlet.
Scantech-ID 3.3 V-1020 USB DRIVER In case you will use the VEGA with USB virtual com port emulation, it is necessary to install the correct USB driver on your POS or Host system, needed for correct operation between your system and the VEGA scanner. You can download this USB driver from the Scantech-ID web site: www. Scantech-ID.
18 Chapter 4 Installation of the VEGA V-1020BT
Scantech-ID 4.1 V-1020BT UNPACKING Unpack the VEGA as follows: 1. Take the VEGA and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered. Standard Shipment Package a. VEGA Area Imager Handheld Bar code Scanner Bluetooth b. Communication Cable (RS-232 or Keyboard wedge or USB) c. Power adaptor d. User Manual e. Bluetooth Cradle or charger(optional) f. Transparent Cover Plate 4.
20 Configuring the VEGA 1. Connect the supplied communication cable at the bottom side of the cradle. 2. Connect the other side of the communication cable to the right connector of your POS or HOST system. 3. Plug the external power supply into the power jack on the bottom of the cradle. 4. Plug the power supply into the AC outlet. 5. Turn on your POS or HOST system. 6. Set up communication between the VEGA scanner and cradle.
Scantech-ID 4.3.1 Pairing Pairing refers to when a VEGA scanner has been linked or paired to a specific cradle by scanning that cradle’s Bluetooth MAC address code, this Bluetooth MAC address code is unique for each cradle. This address code is located on the bottom side of the cradle. The pairing of a VEGA scanner to a cradle is one to one. Only one VEGA scanner can be paired to a cradle at any point in time. 4.3.
22 Configuring the VEGA ATTENTION The VEGA scanner must be charged for a minimum of 8 hours before the scanner can be placed in full operation for the first time. The cradle red led will indicate in red when the scanner is charged. After the battery is full, The charge green light will be light. The charge green light will be off when the scanner leaving from cradle. If the battery power of the VEGA is too low, the VEGA will indicate this with red led and beeper warning.
Scantech-ID 1. The VEGA scanner must scan “Scanner Server Mode ON/Scanner Client Mode Off” barcode, to set the VEGA scanner in server mode. 2. When control the Bluetooth device to search the scanner, enter pin code (default 00:00:00:00) to setup comport. 3. When VEGA scanner is successful connected, scanner will initiate with short beep sounds. Blue and red led will also blink followed by a long beep sound. Blue led will slow flash to finish the set up. 4.3.
24 Configuring the VEGA Chapter 5 Cover Display
Scantech-ID 5.1 SETUP COVER DISPLAY The VEGA scanner has the opportunity to change the decorative cover display on the top of the scanner into a display that can show our own commercial message. 5.1.1 Message Format Create your own commercial message with the following outline format, use thicker paper 5.1.2 Change Cover Display Follow the next instruction steps to change the black Cover Display into the transparent Cover Display, so that your customers can read your own commercial massage.
26 Configuring the VEGA Step 1: Press out the front rubber lid toward the arrow. ➀ Step 2: Pull out the front rubber lid off the main unit. Step 3: Press out top cover rim from the inner lock.
Scantech-ID Step 4: Press out the other side of inner lock and remove the complete cover. ➃ Step 5 Assemble transparent top cover rim into inner lock. ➄ Step 6 Assemble another side transparent top cover rim into the inner lock.
28 Configuring the VEGA Step 7 Insert your commercial message card into the top cover toward the arrow. ➆ Step 8 Assemble the front rubber lid into the main unit toward the arrow.
Scantech-ID Chapter 6 Configuring the VEGA
30 Configuring the VEGA 6.1 PREFACE How to configure the VEGA: The Barcode Programming Feature gives the possibility to change the VEGA scanner settings with use programming codes or with the Utility Tool. 6.1.1 Changing Scanner Settings with Programming Codes You can set-up your VEGA by scan all necessary programming codes for parameters that meet applications. After these scans the VEGA is direct permanently saved.
Scantech-ID In this case you can set-up your VEGA by using the advanced Utility Tool. This tool can be used with the following operation systems: Windows98, Windows2000, Windows XP en Windows Vista. This Utility Tool can be delivered on request. Please contact ScantechID Technical Support Department.
32 Configuring the VEGA 6.
Chapter 7 Programming Codes
34 7.1 RETURN TO DEFAULT 7.1.1 Scan this programming code to set the scanner parameters to factory default: Set the scanner to Factory Default - Reset all configuration parameters to their factory default setting. - After this reset you must select all required parameters that meet applications. 7.1.2 Scan this programming code to set the cradle parameters to factory default: Note: The parameter barcode only used V-1020BT series model. Please don’t used setting for V-1020 series model.
Scantech-ID 7.2 RS-232 MODE PARAMETERS Note: These parameter barcodes only used setting RS-232 interface for V1020.Please don’t used setting for V-1020BT series model. 7.2.
36 9600 19200 38400 57600(*) 115200 128000 230400 256000 460800
Scantech-ID 7.2.2 Data bits Data Bits 7 Data Bits 8(*) 7.2.3 Stop bits Stop Bits 1(*) Stop Bits 2 7.2.
38 7.2.5 Hardware/Software Protocols Timeout compose (ms): 500 compose (ms):1000(*) compose (ms): 1500 compose (ms): 2000 compose (ms): 2550 7.2.
Scantech-ID 7.2.7 RS-232 Parameters–ACK Not Active(*) Active Default: 06H(*) 7.2.
40 7.2.9 Software Protocol–XON/XOFF Active Not Active(*) 7.2.
Scantech-ID 7.2.11 RS-232 Parameters-LRC (Longitudinal Redundancy Check) Not Active(*) Active 7.2.
42 7.2.
Scantech-ID 7.3 BLUETOOTH SCANNER SETUP 7.3.1 Bluetooth Default Setting Default Setting 7.3.2 Scanner Server/Client Mode Scanner Server Mode Barcode Scanner Client Mode Barcode 7.3.3 Sleep Mode Sleep Mode 1 min. ON(*) Sleep Mode 10min.
44 7.3.4 Memory Mode Memory Mode ON Memory Mode OFF(*) Memory Read Memory Clear 7.3.
Scantech-ID 7.3.6 Set Pin Code Charactor (PINCODE max. 6 digits, 0-9and A-Z ASCII CODE) 1) Begin to Set PINCODE 2) Go to the ASCII Tables in 9.10, scan 6 labels that represents the PINCODE.
46 7.4 BLUETOOTH CRADLE SETUP 7.4.1 Set Cradle Pin Code Mode Set Default Security Code Barcode (PINCODE = 000000) Set Security ON Barcode Set Security OFF Barcode 7.4.2 Set Pin Code Barcode (PINCODE max. 6 digits ,0-9,A-Z ASCII CODE ) 1) Begin to Set PINCODE 2) Go to the ASCII Tables in 9.10, scan 6 labels that represents the PINCODE.
Scantech-ID 7.4.3 Set Cradle Interface Barcode Note: These parameter barcodes only used setting RS-232 interface for V1020BT series model. Please don’t used setting for V-1020 series model. Set Cradle Interface Default Barcode (default RS232, 19200, N-8-1) Set Cradle KB Interface Barcode Set Cradle RS232 Interface Barcode Set Cradle USB HID Interface Barcode 7.4.3.
48 1200 2400 4800 9600 <19200> 38400 7.4.3.
Scantech-ID 7.4.3.3 Cradle Stop bits <1 bit> 2 bits 7.4.3.4 Cradle Parity Even Odd Mark Space 7.4.3.
50 ACK/NAK Enable XON/XOFF Enable < XON/XOFF Disable > 7.4.3.6 Cradle Keyboard Wedge mode parameters 1.
Scantech-ID 2. Upper/Lower Case Upper Case Lower Case 3. Send Character by ALT Method Enable 4.
52 5. Time out Between Characters <0 ms> 5 ms 10 ms 25 ms 50ms 100ms 6.
Scantech-ID Spanish French German Swedish Switzerland Hungarian Japanese Belgium Portuguese Denmark
54 Netherlands Turkey Reserved 1 7.5 DECODING SELECTION 7.5.
Scantech-ID BPO ON BPO OFF (*) Canada Post ON Canada Post OFF (*) CODABAR ON CODABAR OFF (*) Codablock A ON Codablock A OFF (*) Codablock F ON Codablock F OFF (*)
56 CODE 11 ON CODE 11 OFF (*) CODE 39 ON (*) CODE 39 OFF CODE 93 ON CODE 93 OFF (*) CODE 128 ON (*) CODE 128 OFF GS1-128 ON (*)
Scantech-ID GS1-128 OFF DATAMATRIX ON (*) DATAMATRIX OFF Dutch Post ON Dutch Post OFF (*) EAN-8 ON (*) EAN-8 OFF EAN-13 ON (*) EAN-13 OFF
58 EAN 128 ON (*) EAN 128 OFF GS1 CC-A/B ON GS1 CC-A/B OFF (*) GS1 CC-C ON GS1 CC-C OFF (*) GS1 DataBar-Omni ON GS1 DataBar-Omni OFF (*) GS1 DataBar-Limited ON
Scantech-ID GS1 DataBar-Limited OFF (*) GS1 DataBar-Expanded ON GS1 DataBar-Expanded OFF (*) Infomail ON Infomail OFF (*) INTERLEAVED 2 of 5 ON INTERLEAVED 2 of 5 OFF (*) Japan Post ON Japan Post OFF (*)
60 Matrix 2 of 5 ON Matrix 2 of 5 OFF (*) MaxiCode ON MaxiCode OFF (*) MicroPDF417 ON MicroPDF417 OFF (*) MSI ON MSI OFF (*) PDF417 ON (*)
Scantech-ID PDF417 OFF Planet ON Planet OFF (*) PLESSEY ON PLESSEY OFF (*) Postnet ON Postnet OFF (*) QR Code ON QR Code OFF (*)
62 Standard 2 of 5 ON Standard 2 of 5 OFF (*) Sweden Post ON Sweden Post OFF (*) Telepen ON Telepen OFF (*) TLC 39 ON TLC 39 OFF (*) UPC-A ON (*) UPC-A OFF
Scantech-ID UPC-E ON (*) UPC-E OFF Note: This step does not include codes for all support Barcode symbologies. For a complete overview of support symbologies see appendix. If you need programming codes for symbologies which are not available in this chapter, please contact Scantech-ID Technical Support department or use VEGA utility tool. 7.5.2 Disable All Symbologies. Disable All Symbologies - Disabled all Symbologies. - Use the“OFF”option to disable individual symbologies.
64 7.6 AUSTRALIAN POST SETTINGS 7.6.
Scantech-ID 7.7 7.7.1 AZTEC SETTINGS Structure Append Mode Active Not Active(*) 7.7.2 Aztec Runes Active Not Active(*) 7.7.
66 7.7.
Scantech-ID 7.8 BPO SETTINGS 7.8.1 Symbology Identifier UDSI-Default"P2"(*) Code Mark-Default"*"(*) 7.8.
68 7.9 CANADA POST SETTINGS 7.9.
Scantech-ID 7.10 CODABAR SETTINGS 7.10.1 Symbology Identifier UDSI-Default"B7"(*) Code Mark- Default"D"(*) 7.10.
70 7.10.3 CLSI Library System Active(insert spaces) Not Active(*) 7.10.4 Check Digit Verification Used Not Used(*) 7.10.
Scantech-ID 7.10.
72 7.11 CODABLOCK SETTINGS 7.11.
Scantech-ID 7.12 CODE 11 SETTINGS 7.12.1 Symbology Identifier UDSI-Default"C1"(*) Code Mark-Default"*"(*) 7.12.
74 7.13 CODE 39 SETTINGS 7.13.1 Symbology Identifier UDSI-Default"B1"(*) Code Mark-Default"*"(*) 7.13.2 Format Standard 43 Characters(*) Full ASCII (Extended) 7.13.
Scantech-ID 7.13.4 Accepted Characters * Only(Standard Code 39)(*) $ Only(Trioptic Code 39) $ and * (Standard and Trioptic Code 39) 7.13.
76 Check Digit Transmitted 7.13.6 Reading Range Extended (*) Normal 7.13.
Scantech-ID 7.14 CODE 93 / CODE 93I SETTINGS 7.14.
78 7.15 CODE 128 / GSI-128 SETTINGS 7.15.1 Symbology Identifier UDSICode 128-Default"B3"(*) UDSIGS1-128-Default"C9"(*) Code MarkCode 128-Default"D"(*) Code MarkGS1-128-Default"D"(*) 7.15.
Scantech-ID 7.15.3 CIP 128 French Pharmaceutical Codes Active Not Active (*) FNC1 Separator Character (GS1-128 norms)-(1Dh)(*) 7.15.
80 7.15.
Scantech-ID 7.15.6 GTIN Processing For GS1-128 Active Not Active (*) 7.15.
82 7.16 DATAMATRIX SETTINGS 7.16.
Scantech-ID 7.17 DUTCH POST SETTINGS 7.17.
84 7.18 EAN /UPC PARAMETERS SETTINGS 7.18.
Scantech-ID ISMN – Active ISMN - Not Active (*) ISSN – Active ISSN - Not Active (*) GTIN Processing – Active GTIN Processing - Not Active (*)
86 7.18.
Scantech-ID 7.18.
88 Transmission OFF 7.18.
Scantech-ID 7.19 GS1 COMPOSITE SETTINGS 7.19.1 EAN/UPC Composite Message Decoding Auto-Discriminate (*) Always Linked Never Linked 7.19.
90 Code Mark–CC-C-Default"*"(*) 7.19.
Scantech-ID 7.20 GS1 DATABAR SETTINGS 7.20.
92 7.21 INFOMAIL SETTINGS 7.21.
Scantech-ID 7.22 INTERLEAVED 2 OF 5 PARAMETERS 7.22.1 Check Digit Verification Not Used (*) Modulo 10 French CIP Not Transmitted (*) Transmitted 7.22.
94 7.22.
Scantech-ID 7.23 JAPAN POST SETTINGS 7.23.1 Symbology Identifier UDSI-Default"P5"(*) Code Mark-Default"*"(*) 7.23.
96 7.24 MATRIX 2 OF 5 SETTINGS 7.24.
Scantech-ID 7.25 MAXICODE SETTINGS 7.25.1 Symbology Identifier UDSI-Default"D2"(*) Code Mark-Default"*"(*) 7.25.2 Mode 0 Active Not Active(*) 7.25.
98 7.26 MICROPDF417 SETTINGS 7.26.1 Symbology Identifier UDSI–Default"C8"(*) Code Mark-Default"*"(*) 7.26.
Scantech-ID 7.27 MSI CODE PARAMETERS SETTINGS 7.27.1 Symbology Identifier UDSI-Default"B8"(*) Code Mark-Default"D"(*) 7.27.
100 7.28 PDF417 SETTINGS 7.28.1 Symbology Identifier UDSI-Default"C7"(*) Code Mark-Default"*"(*) 7.28.2 Irregular PDF Active Not Active(*) 7.28.
Scantech-ID 7.28.
102 Addressee Transmitted Addressee Not Transmitted (*) File Size Transmitted File Size Not Transmitted (*) Checksum Transmitted Checksum Not Transmitted (*)
Scantech-ID 7.29 PLANET SETTINGS 7.29.1 Symbology Identifier UDSI-Default"P1"(*) Code Mark-Default"*"(*) 7.29.
104 7.30 PLESSEY CODE PARAMETERS 7.30.1 Symbology Identifier UDSI–Default"C2"(*) Code Mark-Default"D"(*) 7.30.
Scantech-ID 7.31 POSTNET SETTINGS 7.31.1 Symbology Identifier UDSI-Default"P0"(*) Code Mark-Default"*"(*) 7.31.
106 7.32 QR CODE SETTINGS 7.32.1 Model 1 Control Active Not Active (*) 7.32.
Scantech-ID 7.33 STANDARD 2 OF 5 SETTINGS 7.33.1 Symbology Identifier UDSI-Default"B5"(*) Code Mark-Default"D"(*) 7.33.
108 7.33.
Scantech-ID 7.34 SWEDEN POST SETTINGS 7.34.
110 7.35 TELEPEN SETTINGS 7.35.1 Symbology Identifier UDSI-Default"C6"(*) Code Mark-Default"*"(*) 7.35.
Scantech-ID 7.36 TLC 39 SETTINGS 7.36.1 Symbology Identifier UDSI-Default"H0"(*) Code Mark-Default"*"(*) 7.36.2 Linear Transmission Only Active Not Active (*) 7.36.
112 7.37 MISCELLANEOUS PARAMETERS 7.37.1 Symbology Identifier Symbology Identifier Transmitted Symbology Identifier Not Transmitted(*) With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of barcode is being scanned. Please refer to the table below for matching code Symbology Identifier of codes read in.
Scantech-ID 7.38 PREAMBLES AND POSTAMBLES 7.38.1 Preamble The scanner can be programmed to output Barcode data according the following format: [PREAMBLE STRING] [BAR CODE DATA] Example: To send a in front of the barcode, scan only programming code .
114 7.38.2 Postamble The scanner can be programmed to output Barcode data According to the following format: [BAR CODE DATA] [POSTAMBLE STRING] Example: To send a after of the Barcode, scan only programming code . As a result, the scanner will give the following barcode data output: [BAR CODE DATA] [] Postamble None CR+LF (*) CR LF It could be possible that you need other Postambles, in that case use VEGA utility Tool or contact Scantech-ID Technical Support Department.
Scantech-ID Chapter 8 Operating Settings
116 8.1 SCANNING TRIGGERING A reading session begins (lighting and decode processing on) when beam is activated and stops when beam is deactivated. Continuous Scanning When the scanner is turned on a continuous reading session begins (lighting and decode processing on). Note: The continue scanning mode doesn’t support the V-1020BT. Pulse A reading session begins when beam is activated and stays on until a period of inactivity lasting the time specified by the timeout.
Scantech-ID After a period of inactivity lasting the time specified by the timeout, the scan engine starts flashing, checking for a barcode to be read. When a barcode is detected, the lighting automatically turns on and stays on until another period of inactivity (timeout). After the timeout the scan engine starts flashing again. Level + Flashing This mode allows you the switch between level and flashing mode. When the scanner is turned on it is in flashing mode (see flashing mode for explanation).
118 Autostand This mode allows you to switch from Flashing trigger mode to Level trigger mode. Autostand begins in flashing mode: At power up the lighting and decoding are on (no need to activate the trigger line) and after a period of inactivity lasting the time specified by the trigger timeout, the scanner starts flashing. To switch to Level trigger mode activate the trigger line (press the trigger).
Scantech-ID 8.
120 8.3 GOOD READ MODE When active, the scan engine stops the reading session after a successful decoding. - NOTE: this parameter is NOT used with continuous and continuous + flashing modes.
Scantech-ID 8.4 BUZZER BEEP TONE 8.4.1 Beep Tone Setup High (*) Medium Low 8.4.
122 8.4.3 Beep Duration 60 msec 80 msec (*) 200 msec Off 8.4.
Scantech-ID 8.5 GOOD READ DURATION 8.5.1 Good Read Led Duration 80 msec (*) 0.5 sec 1 sec Off 8.5.
124 8.5.3 Setup Beep On (*) Off 8.
Scantech-ID Chapter 9 Imager settings
126 9.1 IMAGER MODE You can set the best reading performance of your VEGA by adjusting certain imager parameters. To choose the best reading performance, depends on the environment, your used application and type of barcodes. Area mode for decode 1D and 2D barcodes. Linear mode for decode 1D Barcodes. Area mode allows you to set the position of the VEGA in any direction regardless of the orientation of the barcode, and perform a good read on 1D and 2D barcodes.
Scantech-ID Appendixes A. DECIMAL VALUE TABLE.........................123 B. ASCII TABLE.............................................124 C. READABLE SYMBOLOGIES....................125 D. TECHNICAL SPECIFICATIONS................126 E. SCAN MAP.................................................127 F. OVERVIEW PARTNUMBERS....................
128 A.
Scantech-ID B.
130 C.
Scantech-ID D.TECHNICAL SPECIFICATIONS Physical Characteristics Scanner Weight V-1020 Approx. 133g V-1020BT Approx. 180g Cradle Weight Approx. 145g Charger Weight Approx. 135g Material ABS Plastic Connector RJ 45C 10Pins Scanner Dimension 186.8 mm x 81.6 mm x 63.9 mm Cradle Dimension 123.9mm x 120mm x 71.4mm Operational Light source Scan rate Visible Red light 650nm + 10nm 200scans/sec auto adaptive in linear mode. 56 images/sec auto adaptive in 2D mode.
132 Radio Characteristics Bluetooth Module Frequency Band Modulation Method RF Output Power Bluetooth V2.0 Standard 2.402GHz ~ 2.480GHz GFSK for 1Mbps Class 2 (under 4 dBm) Class 1 (under 20dBm) Bluetooth distance range Bluetooth distance range Class 2 up to 10M(33”) Class 1 up to 100M(330”) Environmental Operating Temp. 0°C to 50°C (32°F to 122°F) Storage Temp.
Scantech-ID E.SCAN MAP Typical Reading Distances in 0" 4" 8" 12” 16" 20" 10" 25 8" 20 Data Matrix 7.5 mils 6" 15 PDF417 6.6 mils 4" 10 5 2" 0 0" 5 2" 4" 10 0.125 mm/ 5 mils 15 6" 0.25 mm / 10 mils 8" 20 100% contrast UPC / EAN 10" 25 0.5 mm / 20 mils cm 0 10 20 30 40 50 VEGA Typical Reading Distance: These distances are measured in an office environment (250 lux).
134 VEGA Typical Reading Distances (centimeters) Symbology Density Minimum Maximum Distance Distance Code 39 0.125 mm 7.2 cm 13.1 cm 0.20 mm 3.8 cm 22.5 cm 0.25 mm 3.4 cm 27 cm 0.5 mm 5 cm 44 cm 1 mm 8 cm 83 cm UPC / EAN 0.33 mm 5 cm 32 cm Data matrix 0.191 mm 6.3 cm 17.2 cm 0.254 mm 4.8 cm 22 cm 0.381 mm * 29 cm PDF417 0.16 mm 6.2 cm 15.4 cm 0.254 mm 4.5 cm 23 cm 0.381 mm 4 cm 37 cm *Minimum distance depends on symbology length and scan angle.
Scantech-ID F.OVERVIEW MODEL NUMBERS VEGA with Area Imager Version with RS232 interface: 1. A273002 VEGA V-1020-02 2. A274002 VEGA V-1020BT C2 -02 3. A276002 VEGA V-1021BT C1 -02 Version with KBW interface: 4. A274004 VEGA V-1020BT C2 -04 5. A276004 VEGA V-1021BT C1 -04 Version with USB (HID KBW) interface: 6. A273004 VEGA V-1020-04 7. A274003 VEGA V-1020BT C2 -03 8. A276003 VEGA V-1021BT C1 -03 Version with USB (virtual com port) interface: 9.
136 Scantech-ID BV Nijverheidsweg Noord 60-34 3812 PM Amersfoort The Netherlands Phone: Fax: +31 (0)33 469 84 00 +31 (0)33 465 06 15 E-mail: Internet: info@scantech-id.com www.scantech-id.