Information

Report No.: NBHT20141126U01 Page 12 of 13 pages
Appendix 8
附表 8
Test Items
测试项目
Forced discharge
强制放电
1,1
Test procedure
测试步骤
Each cell shall be forced discharged at ambient temperature by connecting it in series with a
12V D. C, power supply at an initial current equal to the maximum discharge current
specified the manufacturer The specified discharge current is to be obtained by connecting
a resistive load of the appropriate size and rating in series with the test cell, Each cell shall
be forced discharged for a time interval(in hours) equal to its rated capacity divided by the
initial test current(in ampere).
20±5℃的环境温度下,将单个电芯连接在 12V 的直流电源上进行强制放电,此直流电源提
供每个电芯初始电流为制造厂指定的最大放电电流,放电时间为额定容量除以初始电流。
1,2
Sample status
样品状态
C24#~C33#, at first cycle in fully discharged states;
C24#~C33#,在第一个循环完全放电状态
C34#~C43#, after 50 cycles ending in fully discharged states;
C34#~C43#,在第五十个循环完全放电状态;
1,3
Result
测试结果
Sample No.
样品编号
Voltage Before test
测试前开路电压
(V)
Test result
测试结果
Sample No.
样品编号
Voltage Before test
测试前开路电压
(V)
Test result
测试结果
C24#
3,371
O
C34#
3,371
O
C25#
3,371
O
C35#
3,370
O
C26#
3,410
O
C36#
3,391
O
C27#
3,372
O
C37#
3,372
O
C28#
3,393
O
C38#
3,376
O
C29#
3,370
O
C39#
3,371
O
C30#
3,370
O
C40#
3,381
O
C31#
3,373
O
C41#
3,370
O
C32#
3,387
O
C42#
3,370
O
C33#
3,376
O
C43#
3,371
O
Note: D -Disassembly, F-Fire, O- no disassembly, no fire.