A-A
B-B
C-C
A
A
BB
CC
3
0
0
1
0
0
1
00
50
3
4
0
50
3
0
0
Distance to furniture:
1500 mm
But please check to avoid furniture or other furnishings being dried
out due to being too close to the stove.
ASSEMBLY
Minimum 300 mm distance
to flammable materials
Area for
convection air out:
500 cm
2
Area for
convection air in:
350 cm
2
Flammable materials
Flammable materials
Flammable materials
Flammable materials
If the floor contains flammable
materials the height above the
floor must be at least 340 mm.
Installation in connection with flammable material
100 mm gas concrete / 50 mm Rockwool Firebatt slab with alumi-
nium coating
Positioning near non-flammable materials
When positioning near a non-flammable wall/structure, the distance
must be at least 10 mm.
Load-bearing base
You must ensure that the base the stove is to be installed on is load-
bearing with the strength to support the weight of the stove and the
chimney, if necessary. If you are unsure about the strength of the base,
contact a specialist before carrying out the installation.
A front plate of non-flammable material can, for example, be a 10
mm cemented plate
Flammable materials
Flammable materials